SECTION 06B: ELECTRICAL
11
detect relay R15
lights not
working
Relay R15 open circuit
Circuit 64 open
FMI 6
Current
above normal
Output A49 J1:13
internal software fuse
active for overcurrent
Emergency
lights not
working
A49 module failure
Connector C35 corroded
Circuit 64 shorted to ground
Relay R15 low resistance
value (expected value ± 200
ohms)
MID 188 PSID # 44 Emergency Relay (A36 JA:24)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A36 JA:24 but
output not active
Engine will shut
down or cannot
be started
A36 module failure
Relay R21 failure
Connector C2 corroded
Connector C21 corroded
Circuit 911 shorted to battery
FMI 4
Shorted Low
Output A36 JA:24
shorted to ground
Emergency
cutout system
not working
A36 module failure
Relay R21 failure
Connector C2 corroded
Connector C21 corroded
Circuit 911 shorted to ground
FMI 5
Open Circuit
A36 module does not
detect Emergency
Cutout Relay R21
Emergency
cutout system
not working
A36 module failure
Relay R21 open circuit
Circuit 911 open
FMI 6
Current
above normal
Output A36 JA:24
internal software fuse
active for overcurrent
Emergency
cutout system
not working
A36 module failure
Connector C2 corroded
Connector C21 corroded
Circuit 911 shorted to ground
Relay R21 low resistance
value
MID 188 PSID # 101 Emgy & Aisle Lts (A46 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A46 J1:4 but
output not active
Aisle lights
always ON
A46 module failure
Connector C144 corroded
Circuit 5 shorted to battery
FMI 4
Shorted Low
Output A46 J1:4
shorted to ground
Aisle lights not
working
A46 module failure
Connector C144 corroded
Circuit 5 shorted to ground
FMI 6
Current
above normal
Output A46 J1:4
internal software fuse
active for overcurrent
Aisle lights not
working
A46 module failure
Connector C144 corroded
Circuit 5 shorted to ground
Low resistance value
MID 188 PSID # 6 Engine Door Se (A49 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A49 J1:2
Engine door
switch Se30 &
A49 module failure
Se30 failure
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...