SECTION 06B: ELECTRICAL
14
MID 188 PSID # 64 Ent Door Close (A36 JB:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A36 J1:10
Entrance door
cannot be closed
with switch
A36 module failure
Connector C71 corroded
Circuit 49A shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A36 JB:10
Entrance door
cannot be
opened
A36 module failure
Inside switch close Sw32
failure
Connector C71 corroded
Circuit 49A shorted to
ground
MID 188 PSID # 71 Ent open out (A36 JB:15)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A36 J1:15
Entrance door
cannot be
closed
A36 module failure
Sw34 failure
Connector C6 corroded
Circuit 47 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A36 JB:15
Entrance door
cannot be
opened with
switch
A36 module failure
Sw34 failure
Connector C6 corroded
Circuit 47 shorted to ground
MID 188 PSID # 67 Ent Open Sol (A47 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A47 J1:7 but
output not active
Open Solenoid
Valve So5
always ON -
Entrance door
cannot be
closed
A47 module failure
Open solenoid valve So5
failure
Connector C70 corroded
Connector C6 corroded
Circuit 48A shorted to battery
FMI 4
Shorted Low
Output A47 J1:7
shorted to ground
Entrance door
cannot be
opened with
switch
A47 module failure
Open solenoid valve So5
failure
Circuit 48A shorted to ground
FMI 5
Open Circuit
A47 module does not
detect Open Solenoid
Valve So5
Entrance door
cannot be
opened with
switch
A47 module failure
Open solenoid valve So5 open
Circuit 48A open
FMI 6
Current
above normal
Output A47 J1:7
internal software fuse
active for overcurrent
Entrance door
cannot be
opened with
switch
A47 module failure
Circuit 48A shorted to ground
Open solenoid valve So5
shorted internally
MID 188 PSID # 72 Ent Unlk Sol (A47 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
Unlk Solenoid
A47 module failure
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...