SECTION 06B: ELECTRICAL
15
output A47 J1:8 but
output not active
Valve So3 or
Unlk Solenoid
Valve So4 always
ON - Entrance
door cannot be
locked
Unlk solenoid valve So3 failure
Unlk dolenoid valve So4 failure
Circuit 12W shorted to battery
FMI 4
Shorted Low
Output A47 J1:8
shorted to ground
Entrance door
cannot be
unlocked
A47 module failure
Unlk solenoid valve So3 failure
Unlk dolenoid valve So4 failure
Circuit 12W shorted to ground
FMI 5
Open Circuit
A47 module does not
detect Unlk Solenoid
Valve So3 or Unlk
Solenoid Valve So4
Entrance door
cannot be
unlocked
A47 module failure
Unlk solenoid valve So3 open
Unlk dolenoid valve So4 open
Circuit 12W open
FMI 6
Current
above normal
Output A47 J1:8
internal software fuse
active for overcurrent
Entrance door
cannot be
unlocked
A47 module failure
Circuit 12W shorted to ground
Unlk solenoid valve So3 or
So4 shorted internally
MID 188 PSID # 77 Evap Motor Rly (A54 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A54 J1:7 but
output not active
Evaporator fan
always ON
A54 module failure
Evaporator Relay R12 failure
Circuit 67 shorted to battery
FMI 4
Shorted Low
Output A54 J1:7
shorted to ground
Evaporator fan
not working
A54 module failure
Evaporator Relay R12 failure
Circuit 67 shorted to ground
FMI 5
Open Circuit
A54 module does not
detect evaporator
relay R12
Evaporator fan
not working
A54 module failure
Evaporator Relay R12 open
circuit
Circuit 67 open
FMI 6
Current
above normal
Output A54 J1:7
internal software fuse
active for overcurrent
Evaporator fan
not working
A54 module failure
Circuit 67 shorted to ground
MID 188 PSID # 133 Flash RH Sw (A48 J1:12)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A48 J1:12 but
output not active
RH flasher not
working
A48 module failure
Connector C4 corroded
Connector Foot:C corroded
Circuit 23 shorted to battery
FMI 4
Shorted Low
Input A48 J1:12
shorted to ground
RH flasher
always ON
A48 module failure
Foot switch Sw139 failure
Connector C4 corroded
Connector Foot:C corroded
Circuit 23 shorted to ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...