SECTION 06B: ELECTRICAL
16
MID 188 PSID # 130 Flasher LH (A45 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A45 J1:9 but
output not active
LH flasher not
working
A45 module failure
Connector Foot:B corroded
Circuit 21 shorted to battery
FMI 4
Shorted Low
Input A45 J1:9
shorted to ground
LH flasher
always ON
A45 module failure
Foot switch Sw138 failure
Connector Foot:B corroded
Circuit 21 shorted to ground
MID 188 PSID # 37 Foot trap (A45 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:2 but
output not active
Foot damper
Mo4 always
ON
A45 module failure
Foot Damper Mo4 failure
Connector C72 corroded
Circuit 65A shorted to battery
FMI 4
Shorted Low
Output A45 J1:2
shorted to ground
Foot damper
Mo4 not
working
A45 module failure
Foot Damper Mo4 failure
Connector C72 corroded
Circuit 65A shorted to ground
FMI 6
Current
above normal
Output A45 J1:2
internal software fuse
active for overcurrent
Foot damper
Mo4 not
working
A45 module failure
Connector C72 corroded
Circuit 65A shorted to ground
MID 188 PSID # 137 FR Clearance lights (A44 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A44 J1:8 but
output not active
Front Clearance
Lights always ON
A44 module failure
Connector C45 corroded
Circuit 63A shorted to battery
FMI 4
Shorted Low
Output A44 J1:8
shorted to ground
Front Clearance
Lights not
working
A44 module failure
Connector C45 corroded
Circuit 63A shorted to ground
FMI 5
Open Circuit
A44 module does
not detect Front
Clearance Lights
Front Clearance
Lights not
working
A44 module failure
L16 open circuit
Circuit 63A open
FMI 6
Current
above normal
Output A44 J1:8
internal software
fuse active for
overcurrent
Front Clearance
Lights not
working
A44 module failure
Connector C45 corroded
Circuit 63A shorted to ground
MID 188 PSID # 128 Fr Flsh-Mkr LH (A45 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:3 but
output not active
Front LH
flasher and
marker lights
always ON
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 21A shorted to battery
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...