SECTION 06B: ELECTRICAL
18
MID 188 PSID # 148 FrontMkr Lts LH (A45 J1:21)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:21 but
output not active
Front Flasher
LH L62 always
ON
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 46A shorted to battery
FMI 4
Shorted Low
Output A45 J1:21
shorted to ground
Front Flasher
LH L62 not
working
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 46A shorted to ground
FMI 5
Open Circuit
A45 module does not
detect Front Flasher
LH L62
Front Flasher
LH L62 not
working
A45 module failure
Front Flasher LH L62 open
circuit
Circuit 46A open
FMI 6
Current
above normal
Output A45 J1:21
internal software fuse
active for overcurrent
Front Flasher
LH L62 not
working
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 46A shorted to ground
MID 188 PSID # 149 FrontMkr Lts RH (A48 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A48 J1:7 but
output not active
Front Flasher RH
L61 and Marker
L63 always ON
A48 module failure
Connector C243 corroded
Circuit 46 shorted to battery
FMI 4
Shorted Low
Output A48 J1:7
shorted to ground
Front Flasher RH
L61 and Marker
L63 not working
A48 module failure
Connector C243 corroded
Circuit 46 shorted to ground
FMI 5
Open Circuit
A48 module does not
detect Front Flasher
LH L62
Front Flasher RH
L61 and Marker
L63 not working
A48 module failure
Front Flasher RH L61 and
Marker L63 open circuit
Circuit 46 open
FMI 6
Current
above normal
Output A48 J1:7
internal software fuse
active for overcurrent
Front Flasher RH
L61 and Marker
L63 not working
A48 module failure
Connector C243 corroded
Circuit 46 shorted to ground
MID 188 PSID # 56 FrStart Enable Sw (A53 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A53 J1:9 but
switch Sw58 not
active
Engine cannot
be started or
stopped from
rear
A53 module failure
Rear start switch Sw58 failure
Connector C91 corroded
Circuit 85C shorted to battery
FMI 4
Shorted Low
Output A53 J1:9
shorted to ground
Engine cannot
be started from
front
A53 module failure
Rear start switch Sw58 failure
Connector C91 corroded
Circuit 85C shorted to ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...