SECTION 06B: ELECTRICAL
20
shorted to ground
always ON low
beam
Headlight switch Sw2 failure
Connector C71 corroded
Circuit 66 shorted to ground
MID 188 SID # 62 Hi Low Beam (A43 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A43 J1:8 but
switch Sw141 not
active
Headlights
always ON
High beam
A43 module failure
Foot switch Sw141 failure
Connector Foot:A corroded
Connector C71 corroded
Circuit 59 shorted to battery
FMI 4
Shorted Low
Input A43 J1:8
shorted to ground
High Low
Beam
headlights foot
switch not
working
A43 module failure
Foot switch Sw141 failure
Connector Foot:A corroded
Connector C71 corroded
Circuit 59 shorted to ground
MID 188 PSID # 141 High Beam LH (A45 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:6 but
output not active
LH High beam
Headlamp
L60B always
ON
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 57L shorted to battery
FMI 4
Shorted Low
Output A45 J1:6
shorted to ground
LH High beam
Headlamp
L60B not
working
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 57L shorted to ground
FMI 5
Open Circuit
A45 module does not
detect LH High beam
Headlamp L60B
LH High beam
Headlamp
L60B not
working
A45 module failure
LH High beam Headlamp L60B
open circuit
Circuit 57L open
FMI 6
Current
above normal
Output A45 J1:6
internal software fuse
active for overcurrent
LH High beam
Headlamp
L60B not
working
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 57L shorted to ground
MID 188 PSID # 145 High Beam RH (A48 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A48 J1:3 but
output not active
RH High beam
Headlamp
L59B always
ON
A48 module failure
Connector C243 corroded
Circuit 57R shorted to battery
FMI 4
Shorted Low
Output A48 J1:3
shorted to ground
RH High beam
Headlamp
L59B not
working
A48 module failure
Connector C243 corroded
Circuit 57R shorted to ground
FMI 5
Open Circuit
A48 module does not
detect RH High beam
RH High beam
Headlamp
A48 module failure
RH High beam Headlamp
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...