SECTION 06B: ELECTRICAL
21
Headlamp L59B
L59B not
working
L59B open circuit
Circuit 57R open
FMI 6
Current
above normal
Output A48 J1:3
internal software fuse
active for overcurrent
RH High beam
Headlamp
L59B not
working
A48 module failure
Connector C243 corroded
Circuit 57R shorted to ground
MID 188 PSID # 83 Horn (A45 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:20 but
output not active
Electrical horn
L185 and L186
always ON
A45 module failure
Electrical horn L185 or L186
failure
Connector C4 corroded
Connector C101 corroded
Circuit 52A shorted to battery
FMI 4
Shorted Low
Output A45 J1:20
shorted to ground
Electrical horn
L185 and L186
not working
A45 module failure
Electrical horn L185 or L186
failure
Connector C4 corroded
Connector C101 corroded
Circuit 52A shorted to ground
FMI 5
Open Circuit
A45 module does not
detect Electrical horn
L185 or L186
Electrical horn
L185 and L186
not working
A45 module failure
Electrical horn L185 or L186
open circuit
Circuit 52A open
FMI 6
Current
above normal
Output A45 J1:20
internal software fuse
active for overcurrent
Electrical horn
L185 and L186
not working
A45 module failure
Connector C4 corroded
Connector C101 corroded
Circuit 52A shorted to ground
MID 188 PSID # 110 Indir Lts Rly (A49 J1:12)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A49 J1:12 but
output not active
Indirect lighting
always ON
A49 module failure
Indirect Light Relay R13 failure
Circuit 132 shorted to battery
FMI 4
Shorted Low
Output A49 J1:12
shorted to ground
Indirect lighting
not working
A49 module failure
Indirect Light Relay R13 failure
Circuit 132 shorted to ground
FMI 5
Open Circuit
A49 module does not
detect Indirect Light
Relay R13
Indirect lighting
not working
A49 module failure
Indirect Light Relay R13 open
circuit
Circuit 132 open
FMI 6
Current
above normal
Output A49 J1:12
internal software fuse
active for overcurrent
Indirect lighting
not working
A49 module failure
Circuit 132 shorted to ground
Relay R13 coil shorted to
ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...