SECTION 06B: ELECTRICAL
22
MID 188 PSID # 89 Knee down Sol (A41 J1:14)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A41 J1:14 but
output not active
Kneeling down
always ON,
coach cannot
be raised
A41 module failure
Kneeling down solenoid valve
So16 failure
Connector C4 corroded
Connector C172 corroded
Circuit 126F shorted to battery
FMI 4
Shorted Low
Output A41 J1:14
shorted to ground
Kneeling down
not working
A41 module failure
Kneeling down solenoid valve
So16 failure
Connector C4 corroded
Connector C172 corroded
Circuit 126F shorted to ground
FMI 5
Open Circuit
A41 module does not
detect Knee. Down
Solenoid Valve So16
Kneeling down
not working
A41 module failure
Kneeling down solenoid valve
So16 open circuit
Circuit 126F open
FMI 6
Current
above normal
Output A41 J1:14
internal software fuse
active for overcurrent
Kneeling down
not working
A41 module failure
Connector C4 corroded
Connector C172 corroded
Circuit 12W shorted to ground
MID 188 PSID # 93 Knee Down Sw (A41 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A41 J1:7 but
switch Sw10A not
active
Kneeling down
not working
A41 module failure
Kneeling switch Sw10A failure
Connector C71 corroded
Connector C170 corroded
Circuit 126A shorted to battery
FMI 4
Shorted Low
Input A41 J1:7
shorted to ground
Kneeling down
always ON,
coach cannot
be raised
A41 module failure
Kneeling switch Sw10A failure
Connector C71 corroded
Connector C170 corroded
Circuit 126A shorted to ground
MID 188 PSID # 94 Knee Up Sw (A41 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A41 J1:6 but
switch Sw10A not
active
Kneeling up not
working
A41 module failure
Kneeling switch Sw10A failure
Connector C71 corroded
Connector C170 corroded
Circuit 126B shorted to battery
FMI 4
Shorted Low
Input A41 J1:6
shorted to ground
Kneeling Up
always ON,
coach cannot
be lowered
A41 module failure
Kneeling switch Sw10A failure
Connector C71 corroded
Connector C170 corroded
Circuit 126B shorted to ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...