SECTION 06B: ELECTRICAL
23
MID 188 SID # 81 Kneeling Level Se (A46 J1:13)
Type of
fault:
FMI
Description:
Fault
Condition:
Possible Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage
present on
signal A46
J1:13 but
sensor Se79
not active
Momentary switch
function lost, holding
switch will raise coach
past the normal ride
height
A46 module failure
Kneeling level sensor Se79
failure
Connector CSe79 corroded
Circuit ANA-KneeLevel shorted
to battery
FMI 4
Shorted Low
Signal A46
J1:13 shorted
to ground
Momentary switch
function lost, holding
switch will lower coach
below standard
kneeling height and
raise coach above the
normal ride height
A46 module failure
Kneeling level sensor Se79
failure
Connector CSe79 corroded
Circuit ANA-KneeLevel shorted
to ground
MID 188 PSID # 98 Lavatory Fan4 (A52 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A52 J1:4
shorted to ground
Air Exhaust
Fan Mo14 not
working
A52 module failure
Air Exhaust Fan Mo14 failure
Connector C91 corroded
Circuit 225 shorted to ground
FMI 5
Open Circuit
A52 module does not
detect Air Exhaust
Fan Mo14
Air Exhaust
Fan Mo14 not
working
A52 module failure
Air Exhaust Fan Mo14 open
circuit
Circuit 225 open
FMI 6
Current
above normal
Output A52 J1:4
internal software fuse
active for overcurrent
Air Exhaust
Fan Mo14 not
working
A52 module failure
Connector C91 corroded
Circuit 225 shorted to ground
MID 188 PSID # 142 Low Beam LH (A45 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:7 but
output not active
LH Low beam
Headlamp
L60A always
ON
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 58L shorted to battery
FMI 4
Shorted Low
Output A45 J1:7
shorted to ground
LH Low beam
Headlamp
L60A not
working
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 58L shorted to ground
FMI 6
Current
above normal
Output A45 J1:7
internal software fuse
active for overcurrent
LH Low beam
Headlamp
L60A not
working
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 58L shorted to ground
MID 188 PSID # 146 Low Beam RH (A48 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
RH Low beam
A48 module failure
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...