SECTION 06B: ELECTRICAL
24
output A48 J1:4 but
output not active
Headlamp
L59A always
ON
Connector C243 corroded
Circuit 58R shorted to battery
FMI 4
Shorted Low
Output A48 J1:4
shorted to ground
RH Low beam
Headlamp
L59A not
working
A48 module failure
Connector C243 corroded
Circuit 58R shorted to ground
FMI 6
Current
above normal
Output A48 J1:4
internal software fuse
active for overcurrent
RH Low beam
Headlamp
L59A not
working
A48 module failure
Connector C243 corroded
Circuit 58R shorted to ground
MID 188 PSID # 153 Lower Stop Lamps (A50 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A50 J1:6 but
output not active
Lower stop
lamps always
ON
A50 module failure
Circuit 82Low shorted to
battery
FMI 4
Shorted Low
Output A50 J1:6
shorted to ground
Lower stop
lamps not
working
A50 module failure
Circuit 82Low shorted to
ground
FMI 6
Current
above normal
Output A50 J1:6
internal software fuse
active for overcurrent
Lower stop
lamps not
working
A50 module failure
Circuit 82Low shorted to
ground
MID 188 PSID # 181 Lower Washer pmp (A46 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A46 J1:3
shorted to ground
Windshield
washer pumps
Mo19 and Mo20
not working
A46 module failure
Windshield washer pump
Mo19 or Mo20 failure
Connector C4 corroded
Connector C61 corroded
Circuit 53F shorted to ground
FMI 5
Open Circuit
A46 module does not
detect Windshield
washer pumps Mo19
and Mo20
Windshield
washer pumps
Mo19 and Mo20
not working
A46 module failure
Windshield washer pump
Mo19 or Mo20 open circuit
Circuit 53F open
FMI 6
Current
above normal
Output A46 J1:3
internal software fuse
active for overcurrent
Windshield
washer pumps
Mo19 and Mo20
not working
A46 module failure
Connector C4 corroded
Connector C61 corroded
Circuit 53F shorted to ground
MID 188 SID # 71 Master Interlock Sw (A36 JB:16)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A36 JB:16 but
switch Sw140 not
active
Master
Interlock
Bypass not
working
A36 module failure
Circuit Master shorted to battery
FMI 4
Shorted Low
Input A36 JB:16
shorted to ground
Master
Interlock
A36 module failure
Master Interlock Bypass switch
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...