SECTION 06B: ELECTRICAL
25
Bypass
always ON
Sw140 failure
Circuit Master shorted to ground
MID 188 SID # 80 Next Stop Sign (A41 J1:13)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A41 J1:13 but
output not active
Next Stop Light
L310 always
ON
A41 module failure
Connector C70 corroded
Circuit 10 shorted to battery
FMI 4
Shorted Low
Output A41 J1:13
shorted to ground
Next Stop Light
L310 not
working
A41 module failure
Connector C70 corroded
Circuit 10 shorted to ground
FMI 6
Current
above normal
Output A41 J1:13
internal software fuse
active for overcurrent
Next Stop Light
L310 not
working
A41 module failure
Connector C70 corroded
Circuit 10 shorted to ground
MID 188 SID # 70 Next Stop Sw (A42 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A42 J1:9 but
switch Sw5 not active
Next Stop
Request not
working
A42 module failure
Connector C70 corroded
Connector C25A corroded
Circuit 4C shorted to battery
FMI 4
Shorted Low
Input A42 J1:9
shorted to ground
Next Stop
Request
always ON
A42 module failure
Connector C70 corroded
Connector C25A corroded
Circuit 4C shorted to ground
MID 188 SID # 75 Oil Separator (A52 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A52 J1:6 but
output not active
Drain valve
discharge
always ON
A52 module failure
Oil separator L350A failure
Connector C27 corroded
Circuit OilSep shorted to
battery
FMI 4
Shorted Low
Output A52 J1:6
shorted to ground
Drain valve
discharge not
working
A52 module failure
Oil Separator L350A failure
Connector C27 corroded
Circuit OilSep shorted to
ground
FMI 5
Open Circuit
A52 module does not
detect oil Separator
L350A
Drain valve
discharge not
working
A52 module failure
Oil separator L350A open
circuit
Circuit OilSep open
FMI 6
Current
above normal
Output A52 J1:6
internal software fuse
active for overcurrent
Drain valve
discharge not
working
A52 module failure
Connector C27 corroded
Circuit OilSep shorted to
ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...