SECTION 06B: ELECTRICAL
26
MID 188 SID # 78 Open Door Sw (A44 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A44 J1:4 but
output not active
Interlock is
disabled and
the door can be
opened even
above 3m/hr (5
KM/h)
A44 module failure
Inside switch open Sw33 or
Inside switch close Sw32 failure
Connector C72 corroded
Circuit 2mph shorted to battery
FMI 4
Shorted Low
Output A44 J1:4
shorted to ground
Entrance door
cannot be
opened with
Inside switches
A44 module failure
Inside switch open Sw33 or
Inside switch close Sw32 failure
Connector C72 corroded
Circuit 2mph shorted to ground
FMI 5
Open Circuit
A44 module does
not detect Inside
switch open Sw33
or Inside switch
close Sw32
Entrance door
cannot be
opened with
Inside switches
A44 module failure
Inside switch open Sw33 or
Inside switch close Sw32 open
circuit
Circuit 2mph open
FMI 6
Current
above normal
Output A44 J1:4
internal software
fuse active for
overcurrent
Entrance door
cannot be
opened with
Inside switches
A44 module failure
Connector C72 corroded
Circuit 2mph shorted to ground
MID 188 PSID # 19 P Rack Fan (A54 J1:1)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A54 J1:1
shorted to ground
P Rack LH Fan
Mo10 not working
A54 module failure
P Rack LH Fan Mo10 failure
Connector C15, C21, C35 or
C56 corroded
Circuit 44 shorted to ground
FMI 5
Open Circuit
A54 module does not
detect P Rack LH
Fan Mo10
P Rack LH Fan
Mo10 not working
A54 module failure
P Rack LH Fan Mo10 open
circuit
Circuit 44 open
FMI 6
Current
above normal
Output A54 J1:1
internal software fuse
active for overcurrent
P Rack LH Fan
Mo10 not working
A54 module failure
Connector C15, C21, C35 or
C56 corroded
Circuit 44 shorted to ground
MID 188 PSID # 20 P Rack Fan (A54 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A54 J1:2
shorted to ground
P Rack RH Fan
Mo11 not working
A54 module failure
P Rack RH Fan Mo11 failure
Connector C15, C21, C35,
C57 or C75 corroded
Circuit 43 shorted to ground
FMI 5
Open Circuit
A54 module does not
detect P Rack RH
Fan Mo11
P Rack RH Fan
Mo11 not working
A54 module failure
P Rack RH Fan Mo11 open
circuit
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...