SECTION 06B: ELECTRICAL
30
MID 188 PSID # 113 Read Lts Rly (A49 J1:15)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A49 J1:15 but
output not active
Reading
Lights always
ON
A49 module failure
Reading Lights Master Relay
R14 failure
Circuit 74C shorted to battery
FMI 4
Shorted Low
Output A49 J1:15
shorted to ground
Reading
Lights not
working
A49 module failure
Reading Lights Master Relay
R14 failure
Circuit 74C shorted to ground
FMI 5
Open Circuit
A49 module does not
detect Reading Lights
Master Relay R14
Reading
Lights not
working
A49 module failure
Reading Lights Master Relay
R14 open circuit
Circuit 74C open
FMI 6
Current
above normal
Output A49 J1:15
internal software fuse
active for overcurrent
Reading
Lights not
working
A49 module failure
Circuit 74C shorted to ground
Relay R14 coil shorted to ground
MID 188 PSID # 114 Read Lts Sw (A41 J1:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A41 J1:10 but
switch Sw26 not
active
Reading
Lights not
working
A41 module failure
Reading Lamp Switch Sw26 failure
Connector C71 corroded
Circuit 74 shorted to battery
FMI 4
Shorted Low
Input A41 J1:10
shorted to ground
Reading
Lights
always ON
A41 module failure
Reading Lamp Switch Sw26 failure
Connector C71 corroded
Circuit 74 shorted to ground
MID 188 PSID # 131 RearFlsh LH (A51 J1:21)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present
on output A51
J1:21 but output
not active
Rear Flasher Light
LH L71, upper rear
LH L286 and Rear
Side markers LH
L75 always ON
A51 module failure
Connector C91 or C120
corroded
Circuit 21AA shorted to battery
FMI 4
Shorted Low
Output A51 J1:21
shorted to ground
Rear Flasher Light
LH L71, upper rear
LH L286 and Rear
Side markers LH
L75 not working
A51 module failure
Connector C91 or C120
corroded
Circuit 21AA and 21C shorted
to ground
FMI 6
Current
above normal
Output A51 J1:21
internal software
fuse active for
overcurrent
Rear Flasher Light
LH L71, upper rear
LH L286 and Rear
Side markers LH
L75 not working
A51 module failure
Connector C91 or C120
corroded
Circuit 21AA and 21C shorted
to ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...