SECTION 06B: ELECTRICAL
33
above normal internal software fuse
active for overcurrent
not working
Connector C397 corroded
Circuit 231A shorted to ground
MID 188 SID # 77 Step Led light (A43 J1:30)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present
on output A43
J1:30 but output
not active
Step Nozzle Light
L20A always ON
A43 module failure
Connector C6 or C65 corroded
Circuit 35A shorted to battery
FMI 4
Shorted Low
Output A43 J1:30
shorted to ground
Step Nozzle Light
L20A not working
A43 module failure
Connector C6 or C65 corroded
Circuit 35A shorted to ground
FMI 6
Current
above normal
Output A43 J1:30
internal software
fuse active for
overcurrent
Step Nozzle Light
L20A not working
A43 module failure
Connector C6 or C65 corroded
Circuit 35A shorted to ground
MID 188 PSID # 117 StepLts (A47 J1:5)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A47 J1:5 but
output not active
Step Lights L18,
L19 or L20
always ON
A47 module failure
Connector C63 corroded
Circuit 35 shorted to battery
FMI 4
Shorted Low
Output A47 J1:5
shorted to ground
Step Lights L18,
L19 or L20 not
working
A47 module failure
Connector C63 corroded
Circuit 35 shorted to ground
FMI 5
Open Circuit
A47 module does not
detect Step Lights
L18, L19 or L20
Step Lights L18,
L19 or L20 not
working
A47 module failure
Circuit 35 open
FMI 6
Current
above normal
Output A47 J1:5
internal software fuse
active for overcurrent
Step Lights L18,
L19 or L20 not
working
A47 module failure
Connector C63 corroded
Circuit 35 shorted to ground
MID 188 PSID # 165 Tag axle Sw (A43 J1:19)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A43 JB:19 but
output not active
Pressure Tag
Switch Sw64
not working
A43 module failure
Connector C71 or C171 corroded
Circuit 160 shorted to battery
FMI 4
Shorted Low
Input A43 J1:19
shorted to ground
Pressure Tag
Switch Sw64
always ON
A43 module failure
Pressure Tag Switch Sw64 failure
Connector C71 or C171 corroded
Circuit 160 shorted to ground
MID 188 PSID # 152 Tail Lights (A51 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A51 J1:8 but
Tail Lights L72,
L74, L77, L78,
A51 module failure
Connector C119, C91 or
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...