SECTION 06B: ELECTRICAL
34
output not active
L79, L80, L82 or
L83 always ON
C120 corroded
Circuit 46 shorted to battery
FMI 4
Shorted Low
Output A51 J1:8
shorted to ground
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 not working
A51 module failure
Connector C119, C91 or
C120 corroded
Circuit 46 shorted to ground
FMI 5
Open Circuit
A51 module does not
detect Tail Lights
L72, L74, L77, L78,
L79, L80, L82 or L83
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 not working
A51 module failure
Circuit 46 open
FMI 6
Current
above normal
Output A51 J1:8
internal software fuse
active for overcurrent
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 not working
A51 module failure
Connector C119, C91 or
C120 corroded
Circuit 46 shorted to ground
MID 188 SID # 25 Trans Inh Sig (A50 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A50 J1:2 but
output not active
Transmission
Shifting not
working
Transmission ECU failure
A50 module failure
Connector C717 corroded
Circuit 185 shorted to battery
FMI 4
Shorted Low
Output A50 J1:2
shorted to ground
Transmission
Shifting not
working
A50 module failure
Connector C717 corroded
Circuit 185 shorted to ground
FMI 5
Open Circuit
A50 module does not
detect Transmission
ECU
Transmission
Shifting not
working
A50 module failure
Circuit 185 open
Transmission ECU failure
FMI 6
Current
above normal
Output A50 J1:2
internal software fuse
active for overcurrent
Transmission
Shifting not
working
A50 module failure
Connector C717 corroded
Circuit 185 shorted to ground
MID 188 PSID # 168 Trans Neutral Sens (A50 J1:11)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A50 J1:11 but
output not active
Transmission
always on
Neutral
A50 module failure
Connector C717 corroded
Circuit 231 shorted to battery
FMI 4
Shorted Low
Output A50 J1:11
shorted to ground
Transmission
Shifting not
working
A50 module failure
Connector C717 corroded
Circuit 231 shorted to ground
MID 188 PSID # 112 Under Floor lights (A47 J1:20)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A47 J1:20
shorted to ground
Baggage
compartment lights
L176, L177, L180,
L181, L182 or L183
not working
A47 module failure
Connector C6, C2 or C59
corroded
Circuit 10A shorted to ground
FMI 6
Current
Output A47 J1:20 Baggage
A47 module failure
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...