SECTION 06B: ELECTRICAL
36
FMI 5
Open Circuit
A46 module does
not detect Upper
Defrost LH
Heater Res37
Upper Defrost
LH Heater
Res37 not
working
A46 module failure
Upper Defrost LH Heater Res37
failure
Circuit 5A open
FMI 6
Current
above normal
Output A46 J1:1
internal software
fuse active for
overcurrent
Upper Defrost
LH Heater
Res37 not
working
A46 module failure
Connector C45 or CMo5 corroded
Circuit 5A shorted to ground
MID 188 SID # 35 Up Def Heater2 (A46 J1:2)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present
on output A46
J1:2 but output
not active
Upper Defrost
RH Heater
Res37 always
ON
A46 module failure
Connector C45 or CMo5 corroded
Circuit 5B shorted to battery
FMI 4
Shorted Low
Output A46 J1:2
shorted to ground
Upper Defrost
RH Heater
Res37 not
working
A46 module failure
Upper Defrost RH Heater Res37
failure
Connector C45 or CMo5 corroded
Circuit 5B shorted to ground
FMI 5
Open Circuit
A46 module does
not detect Upper
Defrost RH
Heater Res37
Upper Defrost
RH Heater
Res37 not
working
A46 module failure
Upper Defrost RH Heater Res37
failure
Circuit 5B open
FMI 6
Current
above normal
Output A46 J1:2
internal software
fuse active for
overcurrent
Upper Defrost
RH Heater
Res37 not
working
A46 module failure
Connector C45 or CMo5 corroded
Circuit 5B shorted to ground
MID 188 PSID # 43 Upper Brk Lamp (A51 J1:6)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present
on output A51
J1:6 but output
not active
Upper Stop Lights
RH L78 or LH L80
always ON
A51 module failure
Connector C91, C119 or C120
corroded
Circuit 82Up shorted to battery
FMI 4
Shorted Low
Output A51 J1:6
shorted to ground
Upper Stop Lights
RH L78 or LH L80
not working
A51 module failure
Connector C91, C119 or C120
corroded
Circuit 82Up shorted to ground
FMI 6
Current
above normal
Output A51 J1:6
internal software
fuse active for
overcurrent
Upper Stop Lights
RH L78 or LH L80
not working
A51 module failure
Connector C91, C119 or C120
corroded
Circuit 82Up shorted to ground
MID 188 SID # 30 WakeUp Rly (A36 JA:15)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A36 JA:15
shorted to ground
Various systems
not working
depending on relay
A36 module failure
Various WUp Relays failure
Connector C2 or C21 corroded
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...