Section 22: HEATING AND AIR CONDITIONING
PA1593
40
2. A pilot solenoid valve replacement seal kit is
available: 871390.
FIGURE 44: PNEUMATIC WATER VALVE
22330
Valve Troubleshooting
PROBLEM
PROCEDURE
Valve fails
to close
1. Check electrical supply with a
voltmeter. It should agree with
nameplate rating.
2. Check pressure at pilot
solenoid valve inlet. It must be
at least equal to the minimum
pressure stamped on the
nameplate. It should not go
below minimum while valve is
operating.
Valve fails
to open.
1. Check that the closure
member assembly, and that
main actuator and cylinder
springs are free to travel.
2. Check that there is no
restriction to the air escaping
from the actuator casing.
3. Make sure that pilot solenoid
valve operates properly.
8.7
WATER RECIRCULATING PUMP
This vehicle is provided with a Rotron
®
brushless DC sealess water circulation pump
which is located in the engine coolant heater
compartment (Fig. 45). The assembly consists
of a centrifugal pump and an electric motor
which are mounted in a compact assembly.
FIGURE 45: PUMP LOCATION (CENTRAL A/C)
22331
The brushless DC sealess pump requires no
periodic maintenance. The sealess design offers
leak-proof protection and the capability to resist
harsh environmental conditions. The pump
magnetically couples to the brushless DC motor
without a wet seal to wear or replace, this
coupling method also enables easy motor
removal without requiring system draining. The
pump electronically commutated brushless DC
motor provides virtually maintenance-free
operation over time by eliminating brush
maintenance and associated brush motor
failure.
Disassembly of the pump will be necessary only
in the case of a rotor failure or motor failure.
Removal
1. Stop engine and allow engine coolant time
to cool.
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...