5-4 OTHER FEATURES
PA1633 X3-45 Commuter Operator’s Manual
Diesel particulate filter clogging sequence – Instrument cluster telltale light
LEVEL 1
steady
REGENERATION NEEDED
Diesel particulate filter is becoming full
The DPF REGENERATION telltale light illuminates to notify the
driver that a stationary regeneration (parked) will be required
soon. When this lamp is lit, initiate stationary regeneration process
at an appropriate time of day. THERE IS NO URGENCY AT THIS
LEVEL.
LEVEL 2
flashing
REGENERATION REQUIRED
Diesel particulate filter full
If no DPF regeneration occurs after the initial DPF
REGENERATION telltale light illumination, the lamp will begin
blinking and a stationary regeneration should be initiated as soon
as possible in order to prevent from entering into Level 3.
LEVEL 3
flashing
+
ATD SERVICE REQUIRED
ENGINE DERATE ACTIVE
Diesel particulate filter overfull
If the flashing DPF REGENERATION telltale light is still ignored,
the CHECK telltale light will illuminate. In that situation, engine
performance is limited. Perform a parked regeneration
IMMEDIATELY to avoid further derate and prevent from entering
into Level 4.
LEVEL
4
flashing
+
+
ATD SERVICE REQUIRED
ENGINE SHUTDOWN ACTIVE
A serious engine problem has occurred. The DPF may be over its
maximum capacity.
If a stationary regeneration is still not initiated, a standard Engine
Protection Shutdown sequence will occur. All of the following
dashboard lamps will be present:
Blinking DPF REGENERATION telltale light;
Solid CHECK telltale light;
Solid STOP telltale light.
Once engine derate and/or shutdown sequence is completed, a
stationary regeneration must occur to continue vehicle operation.
If the driver continues to operate the vehicle without regeneration,
additional measures will be taken to protect the engine and ATD
from damage, up to and including engine shutdown. Parked
regeneration might no longer be possible.
If engine protection has been initiated and forces the engine
to shut down, you CAN immediately re-start the engine and
perform the necessary steps in order to initiate a stationary
regeneration.
Summary of Contents for X3-45 COMMUTER 2018
Page 1: ...OPERATOR S MANUAL X3 45 COMMUTER COACH...
Page 2: ......
Page 3: ...COACH MANUFACTURER X3 45 COMMUTER OPERATING MANUAL March 2018...
Page 4: ...PA1633 MARCH 2018 Featuring REVISION DESCRIPTION DATE FIRST RELEASE 03 2018...
Page 8: ......
Page 12: ......
Page 70: ...4 36 CONTROLS AND INSTRUMENTS PA1633 X3 45 Commuter Operator s Manual...
Page 108: ...5 38 OTHER FEATURES PA1633 X3 45 Commuter Operator s Manual...
Page 116: ...6 8 STARTING AND STOPPING PROCEDURES PA1633 X3 45 Commuter Operator s Manual...
Page 120: ...7 4 SAFETY FEATURES AND EQUIPMENT PA1633 X3 45 Commuter Operator s Manual KIDDE IMAGES...
Page 128: ...7 12 SAFETY FEATURES AND EQUIPMENT PA1633 X3 45 Commuter Operator s Manual...
Page 148: ...8 20 CARE AND MAINTENANCE PA1633 X3 45 Commuter Operator s Manual...
Page 150: ...9 2 TECHNICAL INFORMATION PA1633 X3 45 Commuter Operator s Manual OVERALL DIMENSIONS...
Page 158: ...9 10 TECHNICAL INFORMATION PA1633 X3 45 Commuter Operator s Manual...
Page 160: ......
Page 164: ......