SECTION 06B: ELECTRICAL
16
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
FMI 5
Open Circuit
A54 module does not
detect evaporator
relay R12
Evaporator fan
not working
•
A54 module failure
•
Evaporator Relay R12 open
circuit
•
Circuit 67 open
FMI 6
Current
above normal
Output A54 J1:7
internal software fuse
active for overcurrent
Evaporator fan
not working
•
A54 module failure
•
Circuit 67 shorted to ground
MID 188 PSID # 133 Flash RH Sw (A48 J1:12)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A48 J1:12 but
output not active
RH flasher not
working
•
A48 module failure
•
Connector C4 corroded
•
Connector Foot:C corroded
•
Circuit 23 shorted to battery
FMI 4
Shorted Low
Input A48 J1:12
shorted to ground
RH flasher
always ON
•
A48 module failure
•
Foot switch Sw139 failure
•
Connector C4 corroded
•
Connector Foot:C corroded
•
Circuit 23 shorted to ground
MID 188 PSID # 130 Flasher LH (A45 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A45 J1:9 but
output not active
LH flasher not
working
•
A45 module failure
•
Connector Foot:B corroded
•
Circuit 21 shorted to battery
FMI 4
Shorted Low
Input A45 J1:9
shorted to ground
LH flasher
always ON
•
A45 module failure
•
Foot switch Sw138 failure
•
Connector Foot:B corroded
•
Circuit 21 shorted to ground
MID 188 PSID # 37 Foot trap (A45 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A45 J1:2 but
output not active
Foot damper
Mo4 always
ON
•
A45 module failure
•
Foot Damper Mo4 failure
•
Connector C72 corroded
•
Circuit 65A shorted to battery
FMI 4
Shorted Low
Output A45 J1:2
shorted to ground
Foot damper
Mo4 not
working
•
A45 module failure
•
Foot Damper Mo4 failure
•
Connector C72 corroded
•
Circuit 65A shorted to ground
FMI 6
Current
above normal
Output A45 J1:2
internal software fuse
active for overcurrent
Foot damper
Mo4 not
working
•
A45 module failure
•
Connector C72 corroded
•
Circuit 65A shorted to ground