SECTION 06B: ELECTRICAL
18
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A36 JB:22 but
switch not in Start
position
Engine will start
on ignition
•
A36 module failure
•
Front start switch Sw83 failure
•
Connector C40 corroded
•
Connector C71 corroded
•
Circuit 84B shorted to battery
FMI 4
Shorted Low
Input A36 JB:22
shorted to ground
Engine cannot
be started from
front
•
A36 module failure
•
Front start switch Sw83 failure
•
Connector C40 corroded
•
Connector C71 corroded
•
Circuit 84B shorted to ground
MID 188 PSID # 126 Front Flash RH (A48 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A48 J1:6 but
output not active
Front Flasher
RH L61 always
ON
•
A48 module failure
•
Connector C243 corroded
•
Circuit 23A shorted to battery
FMI 4
Shorted Low
Output A48 J1:6
shorted to ground
Front Flasher
RH L61 not
working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 23A shorted to ground
FMI 6
Current
above normal
Output A48 J1:6
internal software fuse
active for overcurrent
Front Flasher
RH L61 not
working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 23A shorted to ground
MID 188 PSID # 148 FrontMkr Lts LH (A45 J1:21)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A45 J1:21 but
output not active
Front Flasher
LH L62 always
ON
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 46A shorted to battery
FMI 4
Shorted Low
Output A45 J1:21
shorted to ground
Front Flasher
LH L62 not
working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 46A shorted to ground
FMI 5
Open Circuit
A45 module does not
detect Front Flasher
LH L62
Front Flasher
LH L62 not
working
•
A45 module failure
•
Front Flasher LH L62 open
circuit
•
Circuit 46A open
FMI 6
Current
above normal
Output A45 J1:21
internal software fuse
active for overcurrent
Front Flasher
LH L62 not
working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 46A shorted to ground
MID 188 PSID # 149 FrontMkr Lts RH (A48 J1:7)
Type of
FMI
Fault Condition:
Possible
Possible Causes: