SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
21
MID 188 PSID # 141 High Beam LH (A45 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A45 J1:6 but
output not active
LH High beam
Headlamp
L60B always
ON
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 57L shorted to battery
FMI 4
Shorted Low
Output A45 J1:6
shorted to ground
LH High beam
Headlamp
L60B not
working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 57L shorted to ground
FMI 5
Open Circuit
A45 module does not
detect LH High beam
Headlamp L60B
LH High beam
Headlamp
L60B not
working
•
A45 module failure
•
LH High beam Headlamp L60B
open circuit
•
Circuit 57L open
FMI 6
Current
above normal
Output A45 J1:6
internal software fuse
active for overcurrent
LH High beam
Headlamp
L60B not
working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 57L shorted to ground
MID 188 PSID # 145 High Beam RH (A48 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A48 J1:3 but
output not active
RH High beam
Headlamp
L59B always
ON
•
A48 module failure
•
Connector C243 corroded
•
Circuit 57R shorted to battery
FMI 4
Shorted Low
Output A48 J1:3
shorted to ground
RH High beam
Headlamp
L59B not
working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 57R shorted to ground
FMI 5
Open Circuit
A48 module does not
detect RH High beam
Headlamp L59B
RH High beam
Headlamp
L59B not
working
•
A48 module failure
•
RH High beam Headlamp
L59B open circuit
•
Circuit 57R open
FMI 6
Current
above normal
Output A48 J1:3
internal software fuse
active for overcurrent
RH High beam
Headlamp
L59B not
working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 57R shorted to ground
MID 188 PSID # 83 Horn (A45 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A45 J1:20 but
output not active
Electrical horn
L185 and L186
always ON
•
A45 module failure
•
Electrical horn L185 or L186
failure
•
Connector C4 corroded
•
Connector C101 corroded
•
Circuit 52A shorted to battery