SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
27
•
Circuit OilSep open
FMI 6
Current
above normal
Output A52 J1:6
internal software fuse
active for overcurrent
Drain valve
discharge not
working
•
A52 module failure
•
Connector C27 corroded
•
Circuit OilSep shorted to
ground
MID 188 SID # 78 Open Door Sw (A44 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A44 J1:4 but
output not active
Interlock is
disabled and
the door can be
opened even
above 3m/hr (5
KM/h)
•
A44 module failure
•
Inside switch open Sw33 or
Inside switch close Sw32 failure
•
Connector C72 corroded
•
Circuit 2mph shorted to battery
FMI 4
Shorted Low
Output A44 J1:4
shorted to ground
Entrance door
cannot be
opened with
Inside switches
•
A44 module failure
•
Inside switch open Sw33 or
Inside switch close Sw32 failure
•
Connector C72 corroded
•
Circuit 2mph shorted to ground
FMI 5
Open Circuit
A44 module does
not detect Inside
switch open Sw33
or Inside switch
close Sw32
Entrance door
cannot be
opened with
Inside switches
•
A44 module failure
•
Inside switch open Sw33 or
Inside switch close Sw32 open
circuit
•
Circuit 2mph open
FMI 6
Current
above normal
Output A44 J1:4
internal software
fuse active for
overcurrent
Entrance door
cannot be
opened with
Inside switches
•
A44 module failure
•
Connector C72 corroded
•
Circuit 2mph shorted to ground
MID 188 PSID # 19 P Rack Fan (A54 J1:1)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A54 J1:1
shorted to ground
P Rack LH Fan
Mo10 not working
•
A54 module failure
•
P Rack LH Fan Mo10 failure
•
Connector C15, C21, C35 or
C56 corroded
•
Circuit 44 shorted to ground
FMI 5
Open Circuit
A54 module does not
detect P Rack LH
Fan Mo10
P Rack LH Fan
Mo10 not working
•
A54 module failure
•
P Rack LH Fan Mo10 open
circuit
•
Circuit 44 open
FMI 6
Current
above normal
Output A54 J1:1
internal software fuse
active for overcurrent
P Rack LH Fan
Mo10 not working
•
A54 module failure
•
Connector C15, C21, C35 or
C56 corroded
•
Circuit 44 shorted to ground
MID 188 PSID # 20 P Rack Fan (A54 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A54 J1:2
shorted to ground
P Rack RH Fan
Mo11 not working
•
A54 module failure
•
P Rack RH Fan Mo11 failure