SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
29
•
Parking Brake solenoid valve
So17 shorted to ground
MID 188 PSID # 24 Pass Heat Sol (A54 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A54 J1:8 but
output not active
Pass heat
Solenoid valve
So13 always ON
if R26 is ON
•
A54 module failure
•
Pass heat Solenoid valve
So13 failure
•
Circuit 45 shorted to battery
FMI 4
Shorted Low
Output A54 J1:8
shorted to ground
Pass heat
Solenoid valve
So13 not working
•
A54 module failure
•
Pass heat Solenoid valve
So13 failure if R26 is ON
•
Circuit 45 shorted to ground
FMI 6
Current
above normal
Output A54 J1:8
internal software fuse
active for overcurrent
Pass heat
Solenoid valve
So13 not working
•
A54 module failure
•
Circuit 45 shorted to ground
MID 188 SID # 29 Pass On_Off Sig (A54 J1:21)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A54 J1:21 but
output not active
Pre-Heat
relay R26
always ON
•
A54 module failure
•
Pre-Heat relay R26 failure
•
Circuit 13 shorted to battery
FMI 4
Shorted Low
Output A54 J1:21
shorted to ground
Pre-Heat
relay R26 not
working
•
A54 module failure
•
Pre-Heat relay R26 failure
•
Circuit 13 shorted to ground
FMI 5
Open Circuit
A54 module does not
detect Pre-Heat relay
R26
Pre-Heat
relay R26 not
working
•
A54 module failure
•
Pre-Heat relay R26 open circuit
•
Circuit 13 open
FMI 6
Current
above normal
Output A54 J1:21
internal software fuse
active for overcurrent
Pre-Heat
relay R26 not
working
•
A54 module failure
•
Circuit 13 shorted to ground
MID 188 SID # 63 Pass Rec. Cylinder (A54 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A54 J1:20 but
output not active
Pass Gaz
Cylinder L205
always ON
•
A54 module failure
•
Pass Gaz Cylinder L205 failure
•
Circuit 65P or 0EV3 shorted to
battery
FMI 4
Shorted Low
Output A54 J1:20
shorted to ground
Pass Gaz
Cylinder L205
not working
•
A54 module failure
•
Pass Gaz Cylinder L205 failure
•
Circuit 65P shorted to ground
FMI 5
Open Circuit
A54 module does not
detect Pass Gaz
Cylinder L205
Pass Gaz
Cylinder L205
not working
•
A54 module failure
•
Pass Gaz Cylinder L205 open
circuit
•
Circuit 65P or 0EV3 open
FMI 6
Current
above normal
Output A54 J1:20
internal software fuse
Pass Gaz
Cylinder L205
•
A54 module failure
•
Circuit 65P shorted to ground