SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
33
FMI 4
Shorted Low
Output A50 J1:4
shorted to ground
Rear Clearance Lights
L84, L85, L86, L87,
L88, L89, L90, L285
and L286 not working
•
A50 module failure
•
Connector C91 or C10
corroded
•
Circuit 63, 21C or 23C
shorted to ground
FMI 5
Open Circuit
A50 module does not
detect Rear
Clearance Lights L84
and L85
Rear Clearance Lights
L84, L85, L86, L87,
L88, L89, L90, L285
and L286 not working
•
A50 module failure
•
Circuit 63 open
FMI 6
Current
above normal
Output A50 J1:4
internal software fuse
active for overcurrent
Rear Clearance Lights
L84, L85, L86, L87,
L88, L89, L90, L285
and L286 not working
•
A50 module failure
•
Connector C91 or C10
corroded
•
Circuit 63, 21C or 23C
shorted to ground
MID 188 PSID # 59 Rear Start Sw (A53 J1:11)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A53 J1:11
but output not
active
Rear Start
Switch Sw59
always ON
•
A53 module failure
•
Rear Start Switch Sw59 failure
•
Connector C91 corroded
•
Circuit 85E shorted to battery
FMI 4
Shorted Low
Output A53 J1:11
shorted to ground
Rear Start
Switch Sw59
not working
•
A53 module failure
•
Rear Start Switch Sw59 failure
•
Connector C91 corroded
•
Circuit 85E shorted to ground
MID 188 PSID # 57 RrStart Enable Sw (A53 J1:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on input A53
J1:10 but output
not active at
switch Sw58
Rear Start Selector
Switch Sw58
always ON Rear
Start
•
A53 module failure
•
Rear Start Selector Switch
Sw58 failure
•
Connector C91 corroded
•
Circuit 85D shorted to battery
FMI 4
Shorted Low
Input A53 J1:10
shorted to ground
Rear Start Selector
Switch Sw58 not
working, rear start
switch Sw59 will
not function
•
A53 module failure
•
Rear Start Selector Switch
Sw58 failure
•
Connector C91 corroded
•
Circuit 85D shorted to ground
MID 188 SID # 49 Ser Brake Trans (A51 J1:1)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on output A51
J1:1 but output
Cruise control not
working
•
A51 module failure
•
Connector C717 corroded