Appendix C – Allison Diagnostic Troubleshooting Codes
9
CATEGORY OF RESPONSE
ACTIONS TAKEN
DNS - Do Not Shift
Release lock up (LU) clutch and inhibit lock up operation.
Inhibit shifts from the current attained range.
Turn on the CHECK light.
Display the current attained range in the MONITOR window of the shift
selector.
Blank the SELECT window of the shift selector.
Ignore any range selection inputs from the shift selector.
SOL OFF - SOLenoid
OFF
All solenoids are commanded off, resulting in hydraulic default operation of
the transmission – PCS1 & PCS2 are on hydraulically when off electrically.
RPR - Return to
Previous Range
When the speed sensor ratio or PS1 tests do not pass, the TCM commands
the same range as commanded before the shift.
NNC - Neutral No
Clutches
When certain speed sensor ratio or PS1 tests do not pass, the TCM a
neutral condition with no clutches applied.
DNA - Do Not Adapt
The TCM stops adaptive shift control while the code is active.
DIAGNOSTIC TROUBLESHOOTING CODES (DTC) LIST - ALLISON 5
TH
GENERATION CONTROLS
DTC
Description
CHECK
Light
Inhibited Operation
Description
C1312 Retarder Request Sensor Failed Low
No
May inhibit retarder operation if not
using J1939 datalink
C1313 Retarder Request Sensor Failed High
No
May inhibit retarder operation if not
using J1939 datalink
P0122 Pedal Position Sensor Circuit Low Voltage
No
Use default throttle values. Freezes
shift adapts.
P0123 Pedal Position Sensor Circuit High Voltage
No
Use default throttle values. Freezes
shift adapts.
P0218 Transmission Fluid Over Temperature
Yes
Use default sump temp
P0562 System Voltage Low
No
Inhibit TCC Operation, DNA
P0602 TCM Not Programmed
Yes
Lock in Neutral
P0604 Control module random access memory (RAM)
Yes
Lock in Neutral
P0614 Torque Control Data Mismatch - ECM/TCM
Yes
Allows operation only in reverse
and second range.
P0634 TCM Internal Temperature Too High
Yes
SOL OFF (hydraulic default)
P0642 Sensor Reference Voltage "A" Circuit Low
Yes
Default sensor data used
P0643 Sensor Reference Voltage "A" Circuit High
Yes
Default sensor data used
P0657
Actuator Supply Circuit Voltage 1 Open (HSD 1)
Yes
SOL OFF, DNA, Inhibit TCC
operation, Inhibit main modulation
P0658 Actuator Supply Voltage 1 (HSD1) Low
Yes
DNS, SOL OFF (hydraulic default)
P0659 Actuator Supply Voltage 1 (HSD1) High
Yes
DNS, SOL OFF (hydraulic default)
Summary of Contents for X3-45 VIP 2015
Page 1: ...COACH MANUFACTURER OWNER S MANUAL X3 45 VIP PA1610 Rev 1 February 2015...
Page 6: ......
Page 10: ......
Page 28: ......
Page 134: ......
Page 155: ...Technical Information 9 3 LE MIRAGE XLII OVERALL DIMENSIONS...
Page 156: ...Technical Information 9 4 LE MIRAGE XLII OVERALL DIMENSIONS...
Page 166: ......
Page 170: ......
Page 176: ......