background image

1. Keep the instrument dry.

2. Keep the instrument and battery out of reach of infants 

and children.

3. When the symbol “       ” appears,the batteries are low 

and should be replaced. Ensure that battery polarity 

connections are correct when replacing batteries. If you are 

not using the instrument for a long time, remove the battery.

Ensure that battery polarity connections are correct 
when replacing batteries.

If you are not using the instrument for a long time, remove 

the battery.

AC WIRE WARNING:
AC WIRE WARNING detection feature works 
continuously in Stud scan, Deep scan, and metal scan 
modes. When live AC voltage is detected, the AC 
detection warning indicator icon will appear in the 
display. Use extreme caution under these 
circumstances or whenever live AC wiring is present.

• Using the product without instruction

• Using outside the stated limits

• Deactivation of safety systems and removal of explanatory 

and hazard labels

• Opening of the equipment by using tools (screwdrivers, 

etc.)

• Carrying out modification or conversion of the product

• Use of accessories from other manufacturers without 

express approval

Never attempt to repair the product yourself. In case of 

damage, contact a local dealer.

Refer to section "Technical data", the device is designed for 

using in areas which is habitable for humans. 

Do not use the product in explosion hazardous areas or in 

aggressive environments.

• To understand the safety instructions on the product and 

the instructions in the User Manual.

• To be familiar with local safety regulations relating to 

accident prevention.

• Always prevent access to the product by unauthorized 

personnel.

This instrument can be used to detect wood stud, metal and 

live conductors. It will display signal bar on the center of the 

LCD and make a beep sound out when the instrument is 

near to the object, which ensures a high level of functional 

reliability.

DO NOT ASSUME THESE ARE NO LIVE ELECTRICAL 
WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT 
COULD BE DANGEROUS IF THE WALL CONTAINS A 
LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE 
ELECTRICAL POWER, GAS, AND WATER SUPPLIES 
BEFORE PENETRATING A SURFACE. FAILURE TO 
FOLLOW THESE INSTRUCTIONS MAY RESULT IN 
ELECTRICAL SHOCK, FIRE, AND/OR SERIOUS INJURY 
OR PROPERTY DAMAGE.
ALWAYS TURN OFF POWER WHEN WORKING NEAR 
ELECTRICAL WIRES.

IMPORTANT:

Read before Using

EN

The safety instructions and the user manual 

should be read through carefully before the 

product is used for the first time.

SAFETY INSTRUCTION

PROHIBITED USE

LIMITS OF USE

FUNCTION

AREAS OF RESPONSIBILITY
RESPONSIBILITIES OF THE PERSON IN
CHARGE OF THE INSTRUMENT:

1

2

Summary of Contents for PWDX-F38

Page 1: ...Switzerland PWDX F38 USER MANUAL EN BENUTZERHANDBUCH DE MANUEL UTILISATEUR FR MANUALE UTENTE IT MANUAL DE USUARIO ES HANDLEIDING NL KULLANIM KILAVUZU TR BRUGERMANUAL DK OHJEKIRJA FI BRUKERMANUAL NO WARRANTY LIMITED YEARS 2 ON OFF www prexiso eu com ...

Page 2: ...er Refer to section Technical data the device is designed for using in areas which is habitable for humans Do not use the product in explosion hazardous areas or in aggressive environments To understand the safety instructions on the product and the instructions in the User Manual To be familiar with local safety regulations relating to accident prevention Always prevent access to the product by u...

Page 3: ...6 in 60mm deep E AC Scan Detects live unshielded AC wires up to 2 in 51mm deep Open the battery compartment and insert a 9V battery Pay attention to the polarity Press to turn on off the device Press button to switch to the desired mode ON OFF PRODUCT OVERVIEW 1 INSERT THE BATTERY 2 SWITCHING ON OFF 3 SELECTING THE MEASUREMENT MODE A B C F 1 3 4 7 8 2 6 5 E D 1 2 1 2 CENTER Parts Description A B C...

Page 4: ...r Due to irregularities in plaster thickness it is difficult for this wall detector to locate studs in Stud modes Change to Metal Scan mode to locate the nail heads holding wood lath to the studs If the plaster has metal mesh reinforcement the wall detector may be unable to detect through that material Extremely textured walls or acoustic ceilings When scanning a ceiling or wall with an uneven sur...

Page 5: ...direction and mark the spot where the display bars peak from the reversed direction The midpoint of the two marks is the location of the center of the AC cable D Narrow the detecting field To further pinpoint the location of the AC cable target scan the area again Place the tool on one of the previous marks and click scan button It will reset the tool to a lower sensitivity and narrow the scan are...

Page 6: ...roduct specific treatment and waste management can be downloaded from our homepage The Instrument PWDX F38 has a two year warranty For further information on this contact your dealer This warranty is void if product is used for commercial purposes This warranty is not transferable and does not cover products damaged by misuse neglect accident alterations or use and maintenance other than that spec...