background image

A. Press 

           

button to select METAL MODE.

B. Hold the tool in the air and Click Scan button, the 

decreasing bars will disappear and buzzer will beep on time 

and the sensitivity reset is completed. (This will ensure that 

it calibrates away from any metal objects and gets highest 

sensitivity to metal.)

C. 

Find the metal at highest sensitivity:

 Place the tool flat 

against the wall and the slide slowly across the surface. The 

middle bar will rise up as the tool is getting close to the 

metal. Mark the point where you get the highest metal 

indication( the top indicated arrow will show up and a steady 

beep will sound), Continue in the same direction until 

display bars reduce. Reverse direction and mark the spot 

where the display bars peak from the reversed direction. 

The midpoint of the two marks is the location of the center 

of the metal object.

A. Press 

          

 button to select AC SCAN MODE.

B. Place the tool on the wall and click Scan button, the 

decreasing bars will disappear and buzzer will beep on time 

and the sensitivity reset is completed. 

C. 

Find the metal at highest sensitivity:

 Place the tool flat 

against the wall and the slide slowly across the surface. The 

middle bar will rise up as the tool is getting close to the AC 

cable. Mark the point where you get the highest metal 

indication( the top indicated arrow will show up and a steady 

beep will sound), Continue in the same direction until 

display bars reduce. Reverse direction and mark the spot 

where the display bars peak from the reversed direction. 

The midpoint of the two marks is the location of the center 

of the AC cable.

D. 

Narrow the detecting field:

 To further pinpoint the 

location of the AC cable target, scan the area again. Place 

the tool on one of the previous marks and click scan button. 

It will reset the tool to a lower sensitivity and narrow the 

scan area.

E. Scan in both directions and repeat the step C and D until 

the AC cable is located precisely.

Note: AC Scan will only detect live(hot) unshielded AC 

wiring. Please refer to the AC WIRE WARNING for more 

important details and warnings about AC detection.

D. 

Narrow the detecting field:

 To further pinpoint the 

location of the metal target, scan the area again. Place the 

tool on one of the previous marks and click scan button. It 

will reset the tool to a lower sensitivity and narrow the scan 

area.

E. Scan in both directions and repeat the step C and D until 

the metal is located precisely.

Note: If any bars display on the screen, metal is 

present. Small targets or targets deep within the 

surface may only illuminate some of the bars and not 

the center line or audio tone. In this case, use the 

highest indication to determine the metal position.

6. MEASURING IN METAL MODE.

7. MEASURING IN AC WIRE MODE.

7

8

ON/OFF

ON/OFF

ON/OFF

Figure  A

Figure  B

Figure  C

Technical specifcation

Power supply

1 x 9V alkaline battery

Weight(battery not included)

Dimension

3*7*16cm

142

Measuring depth

Metal

Metal or wood Stud

Non-magnetic metal

Charged wire 100-230 volts

80mm

2in. (50mm)

1) 1/2 in(13mm)
2) 1 in.(25mm)
3) 3/2 in.(38mm)

2.36in. (60mm)

Summary of Contents for PWDX-F38

Page 1: ...Switzerland PWDX F38 USER MANUAL EN BENUTZERHANDBUCH DE MANUEL UTILISATEUR FR MANUALE UTENTE IT MANUAL DE USUARIO ES HANDLEIDING NL KULLANIM KILAVUZU TR BRUGERMANUAL DK OHJEKIRJA FI BRUKERMANUAL NO WARRANTY LIMITED YEARS 2 ON OFF www prexiso eu com ...

Page 2: ...er Refer to section Technical data the device is designed for using in areas which is habitable for humans Do not use the product in explosion hazardous areas or in aggressive environments To understand the safety instructions on the product and the instructions in the User Manual To be familiar with local safety regulations relating to accident prevention Always prevent access to the product by u...

Page 3: ...6 in 60mm deep E AC Scan Detects live unshielded AC wires up to 2 in 51mm deep Open the battery compartment and insert a 9V battery Pay attention to the polarity Press to turn on off the device Press button to switch to the desired mode ON OFF PRODUCT OVERVIEW 1 INSERT THE BATTERY 2 SWITCHING ON OFF 3 SELECTING THE MEASUREMENT MODE A B C F 1 3 4 7 8 2 6 5 E D 1 2 1 2 CENTER Parts Description A B C...

Page 4: ...r Due to irregularities in plaster thickness it is difficult for this wall detector to locate studs in Stud modes Change to Metal Scan mode to locate the nail heads holding wood lath to the studs If the plaster has metal mesh reinforcement the wall detector may be unable to detect through that material Extremely textured walls or acoustic ceilings When scanning a ceiling or wall with an uneven sur...

Page 5: ...direction and mark the spot where the display bars peak from the reversed direction The midpoint of the two marks is the location of the center of the AC cable D Narrow the detecting field To further pinpoint the location of the AC cable target scan the area again Place the tool on one of the previous marks and click scan button It will reset the tool to a lower sensitivity and narrow the scan are...

Page 6: ...roduct specific treatment and waste management can be downloaded from our homepage The Instrument PWDX F38 has a two year warranty For further information on this contact your dealer This warranty is void if product is used for commercial purposes This warranty is not transferable and does not cover products damaged by misuse neglect accident alterations or use and maintenance other than that spec...

Reviews: