0 2. 9 6 3 4. 0 0 02
11
1
Smart Repeater Units
The Smart Repeater™ processing units combine electrical power and data signals from different
sources and provide it for up to six VL5+™ Series Wash Luminaires via a single connector to each
luminaire.
Smart Repeater features:
•
Receives Virtuoso® or Series 200™ data signal, and AC power for electronics through standard,
9-pin Series 200 lamp cable from ACS rack and sends it to connected luminaires.
•
Receives lamp power from conventional dimmers or APS6™/C3™ power supply modules
through standard Socapex-type 19-pin lighting connector and sends it to connected luminaires.
•
Provides a thumbwheel switch for setting the starting address for the six luminaire outputs.
•
Provides Broadcast and Reply LEDs to monitor data traffic.
•
Contains test software for Series 300™ luminaires.
•
Attaches to truss or pipes with two truss hooks and a safety cable.
•
Operates up to six VARI
❋
LITE® VL5™, VL5+™ VL5Arc™, VL5A+™, VL5B™, VL6™, or
VLM™ luminaires; one on each output connector.
•
When using multiple combinations involving the VL6C, use the point system indicated below.
Combinations of luminaires connected to the Smart Repeater unit should not exceed 6 points.
VL5 / VL5+ = 1 point
VL5Arc / = 1 point
VL6 = 1 point
VL6B = 2 points
VL6C / VL6C+ = 2 points
•
Accepts DMX512 protocol from DMX control desks and translates it to Series 300 comm for
DMX control of VARI
❋
LITE luminaires.
Two versions of the unit are available: a standard Smart Repeater unit and a Smart Repeater Plus unit.
The standard unit can operate any of the Series 300 luminaires with the exception of the VARI
❋
LITE
VL7™, VL7B™, and VL7U™ luminaires, which can only be operated with a Smart Repeater Plus
unit.
Smart Repeater Plus Unit
The Smart Repeater Plus unit has the ability to operate all
Series 300 luminaires including the VL7 series spot
luminaires, which require additional power not available with
the standard Smart Repeater unit.
Operation and functionality of the Smart Repeater Plus unit is
identical to the standard unit, with the addition of an active
DMX512 termination switch and fan cooling. The Smart
Repeater Plus unit can control up to six VL7, VL7B or VL7U
luminaires.
Summary of Contents for VL5+
Page 1: ...USER MANUAL 02 9634 0002 VL5 Wash Luminaire VL5Arc Wash Luminaire ...
Page 10: ...VL5 SERIES WASH LUMINAIRE USER MANUAL viii 02 9634 0002 Notes ...
Page 24: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 14 02 9634 0002 Notes ...
Page 60: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 50 02 9634 0002 Notes ...
Page 72: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 62 02 9634 0002 Notes ...
Page 73: ...02 9634 0002 63 APPENDIX A Technical Specifications ...
Page 76: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 66 02 9634 0002 Notes ...
Page 82: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 72 02 9634 0002 Notes ...