Electronics Tray
The electronics tray is located on the back of the power base. See figures 3 and 4. The ammeter, the onboard
charger AC power cord receptacle, the main circuit breaker, the controller connector, and the charger inhibit
connector are all located on the electronics tray.
Ammeter:
The ammeter displays the chargers current output in amps. SeeVI. Batteries and Charging.
Onboard Battery Charger AC Power Cord Receptacle:
This is where the AC power cord plugs into the
onboard charger.
Main Circuit Breaker:
The main circuit breaker is a safety feature built into your Jazzy. When the batteries and
the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage to the
motors and the electronics. If the circuit trips, allow your Jazzy to rest for approximately one minute. Next, push
in the circuit breaker button, turn on the controller, and continue normal operation. If the main circuit breaker
continues to trip repeatedly, contact your authorized Pride provider.
Controller Connector:
This is where the controller connects to the power base.
Charger Inhibit Connector:
Your power chair is equipped with a charger inhibit connector. The charger inhibit
enables the onboard charger to disable the controller during charging. The charger inhibit connector is coded with
colorted dots. The dots are positioned so that you can align the flat side of the male connector with the flat side of
the female connector before making the connection.
CAUTION! Failure to properly align the connectors can result in damage to the controller, the
charger, and the connectors.