background image

2

US

THANK YOU

Thank you for choosing this innovative Pridiom dehumidifier.

This instruction manual describes the many benefits and advanced features 
that this unique product has to offer.

The Pridiom dehumidifier is a large capacity unit designed to run highly ef-
ficiently in places such as: restaurants, bars, printing presses, indoor swim-
ming pools, jacuzzis, garages, animal enclosures, cellars, stores, boat sheds, 
weekend cottages, archives, etc.

Pridiom specialises in complete indoor humidity control.
Our world class products incorporate the latest technological developments 
and are designed to create a quality environment.

It is important that you read these instructions carefully before installing 
and using your new dehumidifier.
Please keep them in a safe place for future reference.
Before using your dehumidifier for the first time, please ensure that it has 
been standing for 2 hours in it’s upright position before it is switched on.

SAFETY

For safety reasons, read this information carefully before operating. Persons 
who are not familiar with this type of product must not use it.

This appliance must be grounded and should only be connected to a ground-
ed 115 V / 60 Hz main supply. The installation must be in accordance with the 
regulations of the country where the unit is used.

The unit is designated for indoor operation.

The dehumidifier is safe, however, as with other electrical appliance, use it 

• 

with care.
This appliance is not intended for use by persons (including children) with 

• 

reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, unless they have been given supervision or instruction 
concerning the use of the appliance by a person responsible for their 
safety.

Summary of Contents for PGD1080HCW

Page 1: ...PGD800HCW PGD1080HCW US Dehumidifier www pridiom com USER MANUAL ES Deshumidificador...

Page 2: ...a safe place for future reference Before using your dehumidifier for the first time please ensure that it has been standing for 2 hours in it s upright position before it is switched on SAFETY For saf...

Page 3: ...cal cable and an earthed plug Should it be necessary to replace this plug at any time you must use an earthed electrical plug Warning Never operate this appliance if it has a damaged cord or plug If t...

Page 4: ...This condensate water then flows safely into a fixed drain The dried air then passes through a final heat exchanger where it is warmed before it re enters the room area at a slightly elevated temperat...

Page 5: ...ful effects of excess mois ture as soon as it is plugged in and switched on When positioning your Pridiom dehumidifier ensure that it is placed on a level surface Best results are obtained when window...

Page 6: ...supporting bracket with at least 5 screws horizontally to the wall use the appropriate fixings for the type of wall Note the unit is heavy approxi mately 55lbs Hang the unit on the bracket the two to...

Page 7: ...it back and closing the grille DRAINAGE Connecting the permanent outlet Connect the pipe to an outlet tube with the correct diameter Push the other end of the tube into a drain making sure that the t...

Page 8: ...ll stop however the fan will continue to run for approximately 15 minutes this will clear the heat exchanger of all collected water Fan speed Press the FAN SPEED SELECT button to select low or high sp...

Page 9: ...95 F Defrost Control The dehumidifier is equipped with an automatic de icing mode to defrost the refrigeration coil during low temperature operation The compressor is switched off whilst the fan conti...

Page 10: ...3 L 70 pt day Air Flow High Speed 253cfm 253cfm Voltage 115 V 115 V Current 800 F 60 rh 6 1 A 6 6 A Frequency 60 Hz 60 Hz Power 800 F 60 rh 0 63kW 0 72kW Phase 1ph 1ph Dimensions in 19 5 x 12 x 27 19...

Page 11: ...11 US...

Page 12: ...a crear un entorno de calidad Es importante leer estas instrucciones con cuidado antes de instalar y usar su nuevo deshumidificador Gu rdelas en un lugar seguro para futura referencia Antes de usar su...

Page 13: ...miento autorizado En caso contrario se podr a llegar a perder la garant a Su deshumidificador Pridiom viene suministrado con una cable el ctrico y un enchufe con toma a tierra Si hubiera que reemplaza...

Page 14: ...nces se forma segura a un drenaje fijo El aire seco pasa entonces por un intercam biador de calor donde se calienta antes de volver a entrar en la zona de la sala a una temperatura ligeramente elevada...

Page 15: ...eso de humedad tan pronto como se enchufe y se active Cuando coloque su deshumidificador Pridiom aseg rese de que est colo cado sobre una superficie nivelada Los mejores resultados se obtienen cuando...

Page 16: ...te al menos con 5 tornillos horizontalmente a la pared utilice las fijaciones apropiadas para el tipo de pared T ngase en cuenta que la unidad pesa aproximadamente 55lb Cuelgue la unidad de la abrazad...

Page 17: ...arlo y cierre la rejilla Alojamiento L mpielo de forma regular con un trapo h medo y un detergente suave para el hogar Mantenimiento Un ingeniero competente deber realizar las operaciones de mantenimi...

Page 18: ...utos esto eliminar toda el agua recogida del intercambiador de calor Velocidad del ventilador Pulse el bot n de SELECCI N DE VELOCIDAD DEL VENTILADOR para se leccionar la velocidad baja o alta La luz...

Page 19: ...ol de descongelaci n El deshumidificador viene equipado con un modo de descongelaci n au tom tico para descongelar la bobina de refrigeraci n durante la operaci n a baja temperatura El compresor se ap...

Page 20: ...d 253 cfm 253 cfm Voltaje 115 V 115 V Corriente 800 F 60 HR 6 1 A 6 6 A Frecuencia 60Hz 60Hz Potencia 800 F 60 HR 0 63kW 0 72kW Fase monofase monofase Dimensiones 19 5 x 12 x 27 19 5 x 12 x 27 Peso ne...