background image

2

3

TEMP Button    :

 Push this button to decrease the indoor 

o

O

temperature setting in 1 F increments to 62 F

NOTE:  

Heat mode is for cooling & heating  models only.

1

TEMP Button    :

 Push this button to increase the indoor 

o

O

temperature setting in 1 F increments to 86 F.

2

MODE Button:

 Each time the button is pressed, the operation 

mode is selected in the sequence of the following:

3

AUTO

COOL

DRY

HEAT

FAN 

Model

Transmission Distance

Lowest Voltage of CPU
Emitting Signal

Rated Voltage

RG51I39/BGCEFU, RG51I39/BGEFU

8m 

3.0V(Dry batteries LR03

2)

2.0V

Performance Features

Features of Remote controller buttons

1. Operating Mode:  AUTO

COOL

 DRY

    HEAT(Cooling only model without) and FAN .
2. Timer Setting Function in 24 hours.
3. Indoor  Setting  Temperature Range: 
4. Full function of LCD (Liquid Crystal Display) 

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

        FOLLOW
             ME

RESET LOCK

1

2

4

5

6

7

3

8

9

10

11

12

13

14

Environment

SET TEMPERATURE(  F)

        SWING

        LED
    DISPLAY

        TURBO

O

O

62 F~ 86 F

O

O

O

23 F~140 F

Remote Controller Specification

RESET Button:

  When  you press the recessed RESET button,  

all current settings are cancelled and the control will return to 
the initial settings.

6

ON/OFF Button:

  Push  this button to start operation,  push the

button again to stop operation.

9

AIR DIRECTION Button: 

Press this button to change the swing

o

angle of the louver.  The swing angle of the louver is 6  for 
each press. When the louver swing at a certain angle which 
would affect the cooling and heating effect of the air conditioner, 
it would automatically change the swing direction . No symbol 
will appear in the display area when press this button.  

FAN SPEED Button:

  Used to select the  Fan Speed in four steps-

 AUTO LOW 

MED or  HIGH. Each time the button is pressed,

the fan speed mode is shifted.

8

TIMER ON Button: 

Press this button to initiate the auto-on time 

sequence. Each press will increase the auto-timed setting in 30
minutes increments. When the setting time displays 10h, each 
press will increase the auto-timed setting 60 minutes increments.
To cancel the auto-timed program, simply adjust the auto-on time
to 0.0.

10

4

5

SWING Button:

  Push this switch button to activate auto 

swing feature of the horizontal louver. Push it again to stop.

LED DISPLAY Button: 

Press this button to clear the digit

display in the air conditioner, press it again to illuminate (Not 
available for the units without LED display window).

7

NOTE: Press and hold       and      buttons together for 3 seconds
will alternate the temperature display between the  C &  F scale.

Summary of Contents for POS091HX

Page 1: ...ir conditioner Please read this owner s manual carefully before using your air conditioner The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details POS091HX POS181HX POS121HX POS241HX PWS091HX PWS241HX PWS121HX PWS181HX ...

Page 2: ...r on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer The remote controller uses two alkaline dry batteries R03 LR03X2 1 Slide the cover of the battery compartment off acc...

Page 3: ...urn to the initial settings 6 ON OFF Button Push this button to start operation push the button again to stop operation 9 AIR DIRECTION Button Press this button to change the swing o angle of the louver The swing angle of the louver is 6 for each press When the louver swing at a certain angle which would affect the cooling and heating effect of the air conditioner it would automatically change the...

Page 4: ... displays TIMER display LOCK Indicator Indicators on display panel Buttons design might be slightly different from the actual one you purchased depending on individual models All the functions described are accomplished by the indoor unit If the indoor unit has no this feature there is no corresponding operation happened when press the relative button on the remote controller Note TIMER OFF Button...

Page 5: ... the indoor unit illuminates Push the ON OFF button again to stop this unit operation Ensure unit is plugged and power is available The OPERATION indicator on the display panel of the indoor unit starts flashing 1 Push the MODE button to select DRY 2 Push the TEMP button to set the desired temperature within a range of O O 62 F 86 F 3 Push the ON OFF button the OPERATION lamp lights and the air co...

Page 6: ...g the TIMER OFF there will be a one half second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display window The effective operation time set by the remote controller for the timer function is limited to the following settings 0 5 1 0 1 5 2 0 2 5...

Page 7: ...Start Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0h on the TIMER ON display 3 Press the TIMER OFF button 4 P...

Page 8: ...he swinging moving direction upward or downward 1 12 13 Cautions 1 When replacing batteries do not use old batteries or different type batteries Otherwise it may cause the remote controller to malfunction 2 If you do not use the remote controller for a few weeks or more remove the batteries Otherwise battery leakage may damage the remote controller 3 The average battery life during normal use is a...

Reviews: