background image

 

Radnice u Rokycan 594 CZ-33828     Czech Republic   sales@primaklima.com   Tel.: 00420 371 795 340   www.primaklima.com 

 

Instructions for PK150-ECblue 

Safety instructions 

Please  read  the  assembly  and  operating  instructions  before  commissioning  Prima  Klima  duct  fans.  Our  fans  are  designed  to 
promote indoor air  in ventilation systems. To avoid the creation of condensation, fans should be isolated in unheated rooms. 
Fans  can  be  commissioned  only  following  successful  installation  in  the  ventilation  system,  or  following  the  installation  of 
protection against contact (EN ISO 13857). Suitable protection systems must be installed to protect the fan against the ingress of 
water from the sewage system. No moving parts may be present in the vicinity of the motor following installation. Fans are not 
suitable for operation in hazardous areas. Fans are allowed for indoor use only and  must  not  come into contact  with liquids. 
Outdoor operation is not possible. The power supply must be interrupted at all poles in the event of necessary maintenance. 
The motor impeller must be stationary before opening or maintenance. All Prima Klima fans have a temperature safety shut-off 
function that switches the engine off in the event of overheating. The engine will restart automatically once it has cooled. 

Transport and storage 

Prima Klima fans are securely factory packed so as to be protected against normal transport conditions. At temperature below 
5° C, special transport conditions are required in order to avoid breakage of plastic, i.e. the box must be handled carefully. The 
fan may not be transported on a connection cable. Avoid exposure to shock and vibration. Fans must be stored in a dry place 
that is protected against the weather and dust and in temperatures between -10 and 45°C.  

Assembly 

The safety instructions detailed above must be observed. Assembly and electrical connection may only be performed by trained 
personnel. The relevant VDE and other applicable regulations must be observed. The electrical connection must be installed in 
accordance with the circuit described in the terminal box. The fan must be mounted in the correct flow direction (arrow on the 
sticker). The fan must be mounted that no vibrations are transmitted to the duct system. Fan noise can be avoided through the 
use of a suitable silencer.  
 
 
The fan mounting bracket can used to anchor the fan.  
Turn the fan to achieve the optimum assembly position.  
Ideally, the power supply should be at the bottom.  

 

Caution !!!!  
The metal mounting bracket  
is not burred - there is 
a risk of injury.

 

 

 
 
RJEC Connector

 can be used to connect the Fan with the PK-EC-Digital fan controller, easy over a standard LAN cable. 

Commissioning 

Before  turning  on  the  fan  on,  check  if  the  electricity  has  been  connected  correctly.  Has  the  protective  conductor  been 
connected?  Has  any  leftover  connection  material  been  removed  from  the  fan?  Commissioning  must  be  checked  by  trained 
personnel in accordance with regulations. 

Maintenance and repair 

The  fan  must  be  disconnected  from  the  power  supply  before  maintenance  or  repair.  The  motor  impeller  must  be  stopped. 
Safety regulations must be complied with. To ensure a long lifecycle, the inside of the fan should be cleaned once per year. If the 
fan isn't running, interrupt the power supply for a few minutes and try again. The motor requires approximately 20 seconds to 
go through its self-checking process before the motor restarts. If the fan still does not work, please contact your dealer. 

 

 

Reviews: