Follow all local and national electrical codes.

For assistance please call Prima Customer Ser

vice at 562-407-3079

IMPORTANT  Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for fixtures. 

Prima is not responsible for any fixture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on 

which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties 

are void if Prima transformers are not used. Prima’s catalogs provide general information and suggestions for proper dimmer usage. Please consult 

our customer service department with any questions regarding dimmer specifics. Prima is not responsible for any damage caused by improper 

dimmer specification and usage. Use only qualified electrician for installation. Adhere to all local and national electrical codes prior to installation.

It is strongly recommended that gloves are used when handling the FIT System track. Oils and dirt from fingers can sometimes permanently

mark the finish. Track should be cleaned with a damp cloth and thoroughly dried before fixture installation.Connectors are available for 

extending track length, turning corners or creating intersections in the run. Great care must be taken to ensure the connector is installed 

properly.

double top power feed - 

22-79226

two piece power feed - 

22-79300

V

FIT I System double top power feed 22-79226 connects and feeds two separate power circuits to two seperate lengths of FIT I track (one

circuit per track length). This is a rigid straight connector. Insert the connector into an open end of a FIT I track length. Secure the 

power feed by tightening the set screws with a flat head screwdriver at the top and bottom of the connector. Insert the transformer’s low voltage 

secondary leads from each circuit into the power entry connectors on the top of the power feed. Using the supplied hex wrench, secure the 

Low voltage leads from 

transformer. 10AWG 

THHN stranded

Low voltage leads from 

transformer. 10AWG 

THHN stranded

Circuit 1

90º

clockwise

gap

no

gap

Circuit 2

W

FIT I System two piece power feed 22-79300 is a versatile piece of hardware that allows powerfeed at any point along the FIT I track length 

in either horizontal or veritcal orientation. There are two distinct feeds, one for the HOT terminal and one for the NEUTRAL terminal. The 

HOT terminal feed makes contact with the internal conductor bar within the track. Before installing the HOT terminal feed, ensure that the top knurled 

knob is unscrewed as much as possible so that there is a significant gap beteween the knurled knobs. Insert the feed into the track slot and rotate 

90º clockwise to lock. Secure the feed by tightening the top knurled knob until there is no gap between the knobs.

HOT

NEUTRAL

Ensure that the top knurled 

knob is unscrewed as much 

as possible before 

installation. There should be 

a gap between the knobs.

Ensure that there is 

no gap between 

the knurled knobs 

before installation.

90º

clockwise

The NEUTRAL terminal feed makes contact with the track’s outer housing which aslo acts as the NEUTRAL terminal of the track circuit. Before 

installation, unscrew the BOTTOM knurled knob until there is NO gap between the knobs. Insert the feed into the track slot about 1/2” from the HOT 

terminal feed. Rotate the feed 90º clockwise to lock. Tighten the bottom knurled knob to secure the feed. NOTE: Power is fed to one slot of the track 

only. Insert the transformer’s low voltage secondary leads into the power entry connectors on the top of the powerfeed. Using the supplied hex 

wrench, secure the transformer leads by tightening the set screws for each wire lead. Transformer low voltage leads must be 10 AWG THHN 

HOT Terminal feed

NEUTRAL Terminal feed

13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com

REV

.033015

prima fit I system

general installation instructions part 11 of 12

NOTE: ALL POWERFEED WIRES FEED THROUGH OUR MOUNTING DISK #CO-036 OR J-BOX COVER PLATE #30-JBP.

            SOLD SEPARATELY. SEE DIAGRAM ON PAGE PART 12 OF 12 FOR REFERENCE.

Summary of Contents for FIT I

Page 1: ...RTANT SAFETY INSTRUCTIONS IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PRODUCT PLEASE CALL PRIMA CUSTOMER SERVICE AT 1 562 407 3079 INSTALLATION INSTRUCTION A READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIT I SYSTEM B DO NOT INSTALL THIS SYSTEM IN DAMP OR WET LOCATIONS C DO NOT INSTALL THIS SYSTEM OR ANY PART WHICH CONTAINS EXPOSED WIRES LESS THAN 7 FEET FROM ...

Page 2: ...ity and well known name brands We will normally send 50W MR16 for spotlights and 50W Xelogen G6 35 lamp for pendants unless otherwise specified differently in the catalog Prima will also ship according to customers specific lamp type or wattage per order Lamps are complimentary thus we will not offer free replacement nor will we issue any credit for lamps However customers may purchase lamps from us ...

Page 3: ... lighting elements and reset the breaker 2 Attempt to turn the system on If the system still trips look inside the transformer housing and make sure all connections are secure and that there is no short If the system stays on you most likely have a problem with one of the lighting elements Re install one element at a time and check if the system works to find the defective element Ensure that the l...

Page 4: ...ailable for extending track length turning corners or creating intersections in the run Great care must be taken to ensure the connector is installed properly FIT I track is constructed of an aluminum housing which doubles as the neutral conductor Each of the two slots of the track include one conductor and one insulator The slots may used as two separate circuits with the proper use of powerfeeds...

Page 5: ...n the knurled knobs before installation Rotate knurled locking ring clockwise to secure the adapter There should now be a gap between the two knobs Ensure that there is no gap between the knurled knobs before installation FIT I SYSTEM TRACK REQUIRES SUPPORT POINTS BE INSTALLED EVERY 4 FIT I SYSTEM TRACK REQUIRES SUPPORT POINTS BE INSTALLED EVERY 4 D l mounted support The following steps cover the ...

Page 6: ...ed the cable through the top hole and tighten the set screw with the hex wrench Further adjustment may be necessary at the end of the installation process Repeat the steps above for post installation adjustment Mounting disk Hex wrench Track bracket Locking knob Mounting screws Anchors If an installation consists of only a single run of FIT I System track mounted in horizontal orientation with cab...

Page 7: ... Adhere to all local and national electrical codes prior to installation It is strongly recommended that gloves are used when handling the FIT I System track Oils and dirt from fingers can sometimes permanently mark the finish Track should be cleaned with a damp cloth and thoroughly dried before fixture installation Mounting stem assembly w mounting disk and track bracket Locking knob Mounting scr...

Page 8: ...g surface so that they align with the holes in the mounting disks Secure the mounting disks to the mounting surface with the included screws 45º Cable support mounting disk should be placed at a 45º angle from the end of the stem Further adjustment may be necessary for leveling the stem Hex Wrench Track locking knob Mounting Screws Anchors Mounting Screws Anchors Support Stem Assembly Cable suppor...

Page 9: ...e properly installed the picture hanger kit may hold up to a 20lb physical load ENSURE THAT ALL KNOBS AND SET SCREWS ARE TIGHTENED 90º clockwise 90º clockwise Tighten lower knob 22 79394 cable Assembly 22 79395 cable assembly H1 I1 I5 I7 I6 I2 I3 I4 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 Tighten upper knob Multiple support units may be used for added stability Multiple support units may be used for added...

Page 10: ...en to ensure the connector is installed properly J The Straight Inline connector for horizontal or vertical orientations has the benefit of being virtually undetectable after installation This connector does not add any length to the over all track run Insert the conductive 22 79232 or non conductive 22 79233 inserts into the conductor hole on one of the track lengths Insert the top and bottom cov...

Page 11: ...upported lamps Contact Prima customer service for the latest updates on which lamps we support and proper usage Prima low voltage transformers must be used with all Prima Lighting product installations All warranties are void if Prima transformers are not used Prima s catalogs provide general information and suggestions for proper dimmer usage Please consult our customer service department with an...

Page 12: ...he transformer leads by tightening the set screws for each wire lead Transformer low voltage leads must be 10 AWG THHN stranded end top power feed 22 79224 two way adjustable power feed 22 79225 R a hinged construction which allows the two track lengths to be positioned at variable angles Insert the connector into open end of a FIT I track length Secure the powerfeed by tightening the set screws w...

Page 13: ...re lead Transformer low voltage leads must be 10 AWG THHN stranded NOTE Power is fed tothe bottom slot three way 90º power feed 22 79228 four way 90º power feed 22 79229 U FIT I System four way 90º power feed 22 79229 connects and feeds power to four lengths of FIT I track The construction of the connector allows the four track lengths to be positioned at 90º angles Insert the connector into open ...

Page 14: ...e supplied hex wrench secure the Low voltage leads from transformer 10AWG THHN stranded Low voltage leads from transformer 10AWG THHN stranded Circuit 1 90º clockwise gap no gap Circuit 2 W FIT I System two piece power feed 22 79300 is a versatile piece of hardware that allows powerfeed at any point along the FIT I track length in either horizontal or veritcal orientation There are two distinct fe...

Page 15: ...ared neutral configuration The circuits are split via the internal conductors while the outer track housing serves as the neutral for both circuits To accomplish this power must be fed from two separate locationson the same track run The example below shows a single run of track with an end feed at each end of the track In one end feed the top power pin is removed so that power is fed to only the ...

Page 16: ...ote Using a dimmer may shorten the secondary length distance ELECTRONIC TRANSFORMERS ARE DIMMABLE Prima recommends the use of 10AWG standard wire on output Attach wires Firmly with wire nuts Voltage Drop Formula WireS ize Gauge 10 10 12 12 12 5 8 10 15 30 300W 200W 150W 100W 50W ACTransformer Class II Electronic Transformers Class I Electronic Transformers MUST USE LOW VOLTAGE ELECTRONIC DIMMER TO...