Follow all local and national electrical codes.
For assistance please call Prima Customer Ser
vice at 562-407-3079
IMPORTANT Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for fixtures.
Prima is not responsible for any fixture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on
which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties
are void if Prima transformers are not used. Prima’s catalogs provide general information and suggestions for proper dimmer usage. Please consult
our customer service department with any questions regarding dimmer specifics. Prima is not responsible for any damage caused by improper
dimmer specification and usage. Use only qualified electrician for installation. Adhere to all local and national electrical codes prior to installation.
It is strongly recommended that gloves are used when handling the FIT System track. Oils and dirt from fingers can sometimes permanently
mark the finish. Track should be cleaned with a damp cloth and thoroughly dried before fixture installation. Connectors are available for
extending track length, turning corners or creating intersections in the run. Great care must be taken to ensure the connector is installed
properly.
two circuit / shared neutral operation
Z
FIT I System track may be powered in a two circuit / shared neutral configuration. The circuits are split via the internal conductors while the
outer track housing serves as the neutral for both circuits. To accomplish this, power must be fed from two separate locations on the same
track run. The example below shows a single run of track with an end feed at each end of the track. In one end feed the top power pin is
removed so that power is fed to only the bottom slot of the track. As well, the other end feed has the bottom power pin removed so as to only
separately from the track heads in the bottom slot.
NOTE: DIMMING IS NOT POSSIBLE WHEN WIRING FIT I SYSTEM IN A TWO CIRCUIT / SHARED NEUTRAL CONFIGURATION.
power pin removal
Insert the pin removal tool
(22-79540) into the powerfeed and
over the pin you wish to remove.
When the tool is fully inserted, rotate
the tool counter clock wise until the
power pin is fully unscrewed.
Remove the tool. The removed power pin will be
inside the tool and can be removed easily by
hand.
End feed with bottom
power pin removed.
End feed with top
power pin removed.
Low voltage leads to
separate remote
transformer for circuit 2.
Support point
(non-powerfeed)
Support point
(non-powerfeed)
NEUTRAL
NEUTRAL
HOT 1
HOT 2
Low voltage leads to
separate remote
transformer for circuit 1.
Circuit 1
Uplight
Circuit 2
Downlight
Circuit 2
Downlight
Powers the bottom slot only.
Powers the top slot only.
Now when power is connected to this
end feed, the top slot will be dead
and power will be available for the
bottom slot only.
13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com
REV
.033015
30-JBP
CO-036
Option #1
Option #2
prima fit I system