PRIMA LIGHTING - FIT I INSTALLATION MANUAL

CAUTION

1. Failure to properly install low voltage electrical products may void the warranty. Please ensure the proper 

electrical connections as follows:

• Follow instruction guidelines when wiring and installing tran

sformers.

Firmly connect the transformer’s secondary leads to the FIT I System track as described in the power

feed instruction sheets.

ting connections at all conductive 

Be sure the lamp is firmly seated in the socket.

Check to ensure that no wires, cables or packing materials are crossing both conductors of the 

FIT I track.

2. Make sure all power connections are tight. Follow this procedure to ensure proper connection:

   

• Read all transformer instruction sheets before installation.

• Turn on the power only after system installation is complete.

• 60 minutes after power-up, check for excess heat at power con

nection areas.

• Tighten any connections that feel hot and assure to use 10 AWG THHN single standard wire from 

transformer to powerfeed. The use of this wire is to maintain the standard 25 amp capacity.

• Do not use Romex cable or MC rigid cable for secondary wire c

onnections.

For long distance remote connections, please refer to the voltage drop table in the back of this 

instruction manual.

3.

Measure voltage after the installation is complete.

Secondary voltage for 12V system should be between 11.3V 

to 11.7V with 85% to 90% load without dimmer, and for 24V system should be between 22.6V to 23.4V  

Since electronic transformers run at a higher frequency, the u

se of a high-end voltage meter such as  

Fluke 87 is recommended.

4

.

Always turn off the power and allow the system to cool before at

tempting any adjustments such as moving 

powerfeeds, adjusting pendant cable lengths, moving trackheads or changing light bulbs.

5.

Prima Lighting includes lamps for each fixture we ship. The lamps included are top quality and well-

known name brands. We will normally send 50W MR16 for spotlights and 50W Xelogen G6.35 lamp for 

pendants unless otherwise specified differently in the catalog. P

rima will also ship according to customers’ 

specific lamp type or wattage per order. Lamps are complimentary

, thus we will not offer free replacement, 

nor will we issue any credit for lamps. However, customers may 

purchase lamps from us and receive standard

lamp warranty.  We always encourage our customers to purchase r

eplacement lamps directly from us 

when replacements are needed. 

6

. If systems are ordered without transformers, all warranties are void and complimentary lamps will not be 

 

 

 

 

 

   

 

 

 

 

 

 

 

supplied.

11

.

If you experience problems or irregular function of the system,

 stop the installation immediately and contact 

Prima Lighting Customer Service for assistance.

 

 

 

   

 

13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com

 FIT I interconnecting joints.

with 85% to 90% load without dimmer. Magnetic transformers may 

be tested with most voltage meters. 

7.  

The maximum permissible load allowed on any Prima Rail circuit 

is 25 amps. The rail can be operated at 12 volts 

with a 300W maximum load or at 24 volts with a 600W maximum loa

d.

8.  

9. 

 When cleaning FIT I System track, be sure to use a clean damp 

cotton cloth.

Prima Lighting systems are listed by ETL. Our system products a

re only listed when used as a complete system. All 

components, including transformers, must be provided by Prima Lighting. The substitution of Prima products with 

another manufacturer’s product will render the listing completely void. Prima Lighting is removed from liability 

 

and any insurance to which you may be entitled will be jeopardized.

Questions or problems you can’t find answered here? Call 1-562-407-3079 during regular business hours 

(Monday-Friday 7:00-4:00pm PST).

CAUTION! Bulbs, metal, and other parts of elements may become hot. Use protective gloves and adjust 

 

  

 

  

 

 

 

 

 

 

 

 

 

elements by their coated handles and cords.

 

RE

V. 033015

10. Do not apply any paint material over our tracks and connectors.

Summary of Contents for FIT I

Page 1: ...RTANT SAFETY INSTRUCTIONS IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PRODUCT PLEASE CALL PRIMA CUSTOMER SERVICE AT 1 562 407 3079 INSTALLATION INSTRUCTION A READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIT I SYSTEM B DO NOT INSTALL THIS SYSTEM IN DAMP OR WET LOCATIONS C DO NOT INSTALL THIS SYSTEM OR ANY PART WHICH CONTAINS EXPOSED WIRES LESS THAN 7 FEET FROM ...

Page 2: ...ity and well known name brands We will normally send 50W MR16 for spotlights and 50W Xelogen G6 35 lamp for pendants unless otherwise specified differently in the catalog Prima will also ship according to customers specific lamp type or wattage per order Lamps are complimentary thus we will not offer free replacement nor will we issue any credit for lamps However customers may purchase lamps from us ...

Page 3: ... lighting elements and reset the breaker 2 Attempt to turn the system on If the system still trips look inside the transformer housing and make sure all connections are secure and that there is no short If the system stays on you most likely have a problem with one of the lighting elements Re install one element at a time and check if the system works to find the defective element Ensure that the l...

Page 4: ...ailable for extending track length turning corners or creating intersections in the run Great care must be taken to ensure the connector is installed properly FIT I track is constructed of an aluminum housing which doubles as the neutral conductor Each of the two slots of the track include one conductor and one insulator The slots may used as two separate circuits with the proper use of powerfeeds...

Page 5: ...n the knurled knobs before installation Rotate knurled locking ring clockwise to secure the adapter There should now be a gap between the two knobs Ensure that there is no gap between the knurled knobs before installation FIT I SYSTEM TRACK REQUIRES SUPPORT POINTS BE INSTALLED EVERY 4 FIT I SYSTEM TRACK REQUIRES SUPPORT POINTS BE INSTALLED EVERY 4 D l mounted support The following steps cover the ...

Page 6: ...ed the cable through the top hole and tighten the set screw with the hex wrench Further adjustment may be necessary at the end of the installation process Repeat the steps above for post installation adjustment Mounting disk Hex wrench Track bracket Locking knob Mounting screws Anchors If an installation consists of only a single run of FIT I System track mounted in horizontal orientation with cab...

Page 7: ... Adhere to all local and national electrical codes prior to installation It is strongly recommended that gloves are used when handling the FIT I System track Oils and dirt from fingers can sometimes permanently mark the finish Track should be cleaned with a damp cloth and thoroughly dried before fixture installation Mounting stem assembly w mounting disk and track bracket Locking knob Mounting scr...

Page 8: ...g surface so that they align with the holes in the mounting disks Secure the mounting disks to the mounting surface with the included screws 45º Cable support mounting disk should be placed at a 45º angle from the end of the stem Further adjustment may be necessary for leveling the stem Hex Wrench Track locking knob Mounting Screws Anchors Mounting Screws Anchors Support Stem Assembly Cable suppor...

Page 9: ...e properly installed the picture hanger kit may hold up to a 20lb physical load ENSURE THAT ALL KNOBS AND SET SCREWS ARE TIGHTENED 90º clockwise 90º clockwise Tighten lower knob 22 79394 cable Assembly 22 79395 cable assembly H1 I1 I5 I7 I6 I2 I3 I4 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 Tighten upper knob Multiple support units may be used for added stability Multiple support units may be used for added...

Page 10: ...en to ensure the connector is installed properly J The Straight Inline connector for horizontal or vertical orientations has the benefit of being virtually undetectable after installation This connector does not add any length to the over all track run Insert the conductive 22 79232 or non conductive 22 79233 inserts into the conductor hole on one of the track lengths Insert the top and bottom cov...

Page 11: ...upported lamps Contact Prima customer service for the latest updates on which lamps we support and proper usage Prima low voltage transformers must be used with all Prima Lighting product installations All warranties are void if Prima transformers are not used Prima s catalogs provide general information and suggestions for proper dimmer usage Please consult our customer service department with an...

Page 12: ...he transformer leads by tightening the set screws for each wire lead Transformer low voltage leads must be 10 AWG THHN stranded end top power feed 22 79224 two way adjustable power feed 22 79225 R a hinged construction which allows the two track lengths to be positioned at variable angles Insert the connector into open end of a FIT I track length Secure the powerfeed by tightening the set screws w...

Page 13: ...re lead Transformer low voltage leads must be 10 AWG THHN stranded NOTE Power is fed tothe bottom slot three way 90º power feed 22 79228 four way 90º power feed 22 79229 U FIT I System four way 90º power feed 22 79229 connects and feeds power to four lengths of FIT I track The construction of the connector allows the four track lengths to be positioned at 90º angles Insert the connector into open ...

Page 14: ...e supplied hex wrench secure the Low voltage leads from transformer 10AWG THHN stranded Low voltage leads from transformer 10AWG THHN stranded Circuit 1 90º clockwise gap no gap Circuit 2 W FIT I System two piece power feed 22 79300 is a versatile piece of hardware that allows powerfeed at any point along the FIT I track length in either horizontal or veritcal orientation There are two distinct fe...

Page 15: ...ared neutral configuration The circuits are split via the internal conductors while the outer track housing serves as the neutral for both circuits To accomplish this power must be fed from two separate locationson the same track run The example below shows a single run of track with an end feed at each end of the track In one end feed the top power pin is removed so that power is fed to only the ...

Page 16: ...ote Using a dimmer may shorten the secondary length distance ELECTRONIC TRANSFORMERS ARE DIMMABLE Prima recommends the use of 10AWG standard wire on output Attach wires Firmly with wire nuts Voltage Drop Formula WireS ize Gauge 10 10 12 12 12 5 8 10 15 30 300W 200W 150W 100W 50W ACTransformer Class II Electronic Transformers Class I Electronic Transformers MUST USE LOW VOLTAGE ELECTRONIC DIMMER TO...

Reviews: