background image

Fitting Guide

Primera anti-ligature locksets are not a DIY product.  Installation should be carried out by a qualified trades 

person suitably equipped to facilitate a professional installation. These guidelines assume that the installer is 

familiar with the general principles of lock installation and as such, serve only to provide additional guidance 

on some of the more specific issues relating to the installation of Primera anti-ligature lock sets.
1)  Decide the optimum position for the lock on the door. Then mark out and prepare a mortise hole 18W 

x 110D x 175H (mm). The hole must be vertical and central to the core of the door and there must be 

sufficient clearance for the lock to centrally align in the mortise pocket. Adjust accordingly for doors with a 

leading edge. Ensure that the mortise is free from all debris.

2)  Carefully review the exploded view on page 1. For models 

76

 ,  

86

  &  

96

  please go straight to section 4.  

3)  For models  

46

 ,  

56

  &  

66

  (where Turn/Pull PR4-728-TP is supplied) using the template provided, mark 

the 5 internal and 3 external reference points and drill the door to the size detailed. Care should be taken to 

ensure accuracy and that the holes are in horizontal alignment. Place the lock back in the mortise to check 

alignment and adjust if required. 
4)  Continuing with the template, mark out and neatly drill for the installation of the locking cylinder ensuring 

that the hole is in horizontal alignment. Do not remove more material than is absolutely necessary. Please 

ensure sufficient clearance for the back of the single Euro cylinder on models  

46

 ,  

56

 ,  

66

  &  

76

  as shown 

in figure 1A. 
5)  Models  

86

  &  

96

  require a through hole for the key-key cylinder. Locks with a PR2, PR3 & PR3S prefix 

are supplied with an important Secondary Barricade Override safety feature. They must be configured to 

ensure nursing staff can gain access to the spindle concealed under the external escutcheon plate. This is 

achieved by removal of the anti-tamper screw(s) and moving the slider on the escutcheon plate to access the 

spindle. Please refer to page 4 for specific information on the installation of this model.
6)  After following the specific door preparation guidelines for this model detailed overleaf, please install the 

remainder of the ironmongery according to the exploded view and, where Turn/Pull PR4-728-TP is  supplied, 

in the following order:
A)  With the lock inserted (not screwed) in to the mortise hole, 

offer the round Turn/Pull and 8mm spindle on to the door. The 

spindle should go in to the lock follower and allow the Turn to 

sit flat against the surface of the door 

without force. 

If the Turn 

does not sit freely against the surface of the door then the lock 

is  out  of  alignment  in  the  mortise which  should  be  adjusted 

accordingly. 

Important: 

If  force  is  used  to  pull  the Turn/Pull 

back to the door this will lead to binding, difficult operation and 

possibly premature failure.

B)  Cut the 2 x M5 Torx Pin machine Screws to the correct length to ensure sufficient penetration in to the 

Turn/Pull screw ports. If the screws are cut too long  the Turn/Pull will not pull firmly back against the surface of 

the  door  resulting  in  a  ligature  risk!  Secure  the Turn/Pull  on  to  the  door  fastening  the  screws  through  the 

Twin-Tech escutcheon assembly. 
Take care not to over-tighten the fixing screws!

IMPORTANT:  When installed correctly the 

Turn/Pull should not pass through the horizontal 

position.

C)  Install  the  locking  cylinder  using  the  screw 

provided again ensuring horizontal alignment. Do not over tighten the cylinder retaining screw as this will 

restrict the movement of the key and, in extreme cases can cause the cylinder to collapse. We recommend 

that final adjustment is undertaken by hand.  Check that the key turns freely and will throw and withdraw the 

lock bolt. 

Important: 

With the Turn/Pull held rigid the key should withdraw the bolt.

WARNING: 

 This  lock  should  only  be  used  with 

cylinders where the cam comes to rest as shown at 

Fig ‘A’ when the key is removed.
If  using  multi-positioned  cam  cylinders  it  is 

essential  that  the  cam  is  positioned  accordingly. 

Without this the emergency override feature may 

not work which could cause damage to the lock.

 

D)  Secure  the  lock  in  the  mortise  hole  with  the  anti-tamper  screws  provided  and  attach  face-plate. 

Reconfirm that the Turn/Pull and key still operate the lock freely.
E)  According to the exploded view, align all remaining fittings and fasten to door using the anti-tamper screws 

provided. All plates should be secured flat to the surface of the door to prevent ligature risk! Shorter 5/8ths

 

screws are provided in the fixing pack for circumstances where the 1” screws clash with the lockcase. 
F)  Finally, mark out and install the strike plate. To adjust the roller catch please refer to magnified view on 

page 1. With the door in the closed position, operate the lock to ensure that the bolt travels freely between 

the locked and unlocked positions.

CL

CL

14

110

18

25

83

Backset

Clearance required for

back of cylinder on locksets.

46

 , 

56

 , 

66

 , 

76

 )

For further guidance please contact our Technical Help Line on:

0044 (0) 1253 508643

Fig.1

Fig.6

Fig.7

Fig.4

Fig.5

Fig. 2

Fig.1a

B

A

Position of the cam when key removed.

IMPORTANT:

 

The angle of the tabs 

on the strike plate are factory set. 

Under no circumstances should 

these be adjusted. Doing so could 

cause a lock-out!

IMPORTANT:

 

In the interests of safety, when installing the strike plate in 

the frame of the door drill a 19mm

Ø

 hole to a depth no greater than 

5.5mm from the face of the frame. This will ideally allow the the tabs on 

the strike plate to rest against the base of the hole as shown in Fig 8.  

Fig.9

Fig.8

5.5mm Maximum

Frame of the door from above.

19mm 

Ø

   

IMPORTANT:

 

If the strike plate included in this kit does not carry the                         logo it is not a genuine part. 

Fitting an unbranded strike plate will invalidate the warranty of the lock. In such circumstances please refer to 

your supplier.