12
Chapter 1 Component Names and Functions
1.2 Server (Rear View)
The following are the component names of the server (rear view).
2
5
3
4
4
8
9
7 6
1
[Default]
1
Network blade slot 1/2
The slot number is "NET1" and "NET2" displayed on
the chassis.
Up to two Switch Blades or GbE Pass-Thru Blades, etc.
can be installed.
2
Network blade slot 3/4
The slot number is "NET3" and "NET4" displayed on
the chassis. Up to two Switch Blades, GbE Pass-Thru
Blades or FC Pass-Thru Blades, etc. can be installed.
3
System fan unit
4
Power Supply Unit (PSU) 4/3/2/1
The PSU is installed in slot 1/2 and the dummy PSU is
installed in 3/4 by default.
There are 2 chassis cooling fans and 1 power cooling
fan installed in the PSU.
There are 3 chassis cooling fans installed in the dummy
PSU. The dummy PSU does not supply power.
When added to the PSU it enables redundancy of the
power supply.
5
Management Blade
Two Management Blades are installed by default. The
redundant management function can be used.
6
KVM connector
Connect the KVM cable and then connect the keyboard,
display and mouse.
7
Rear maintenance LED
This works in conjunction with the front maintenance
LED and lights/blinks in the cases below. The LED
colors vary depending if the default KVM module is
used or an optional advanced KVM module is installed.
8
Rear maintenance switch (
)
Pressing this switch turns the front and rear maintenance
switch LEDs ON.
9
KVM module slot
One KVM module is installed. When installing an
optional advanced KVM module, a LAN connector
(10BASE-T/100BASE-TX) for remote console is also
added apart from the parts listed in 6 - 8.
LED status
Server Status
Default
Advanced
KVM
module
Blinking
(Amber)
Blinking
(Green)
An error in an internal component
of the server has been detected.
Contact an office listed in the
"Contact Information" of "Start
Guide" or device administrator.
ON
(Amber)
ON
(Green)
This can be turned on by pressing
the front maintenance switch or
using the "System Indication LED
Display" function in the
management terminal. For details
about the "System Indication LED
Display" function refer to "BX600
Management Blade Hardware
Guide" and "ServerView User’s
Guide".
ID