AIR 40, AIR Breeze, AIR 30, AIR X MARINE and AIR SILENT-X are trademarks of Primus Wind Power 2013 Primus Wind Power Inc.
AIR Owner’s Manual
3-CMLT-2020-A
51
APPENDIX: C
AIR Storage Kit, P/N 2-ARAL-ST-100
PARTS INCLUDED (in caption below):
AIR 30 Hub – 3-CMBP-1005-01
AIR X Marine Nose cone – 3-CMBP-1007-02
Super Lube Multi-Purpose Synthetic Grease with Syncolon (clear) - 3-CAOT-101
Rotor Jam Nut (to secure hub) – 3-HDNT-912
5/16 short arm hex key-3- CAOT-1007 (for rotor jam nut)
CAUTION - When the AIR turbine is stored outdoors for an extended peri-
od, it is critical the nose cone and hub remain in place, as this prevents
water infiltration through the shaft/bearing gap and into the turbine body
(nacelle).
DANGER - If turbine is stored when the Blade/Hub/Nose Cone Assembly is
removed, there is a high probability that water infiltration will occur and
the nacelle interior will rust causing damage. This will not be covered un-
der the Primus Wind Power warranty. To avoid this potential issue, Pri-
mus Wind Power offers the AIR Storage Kit.
INSTRUCTIONS - When storing your turbine, remove the Blade/Hub/Nose
Cone Assembly and store in safe location to not damage blade set. When
The Shaft and Face is exposed, apply a liberal amount of synthetic grease to
the gap around Shaft and Bearing on the Face of the turbine (this should be
performed as a regular maintenance event every 12 months). Next, attach
Hub and Jam Nut and tighten using 5/16” hex key (hand tighten). Attach the
Nose Cone with position of the Nose Cone Blade opening not lined up with
Blade bolt holes to avoid water intrusion through holes in the Hub.
If you have any questions, please feel free to call Primus Technical Support
at 303.235.5820 ext. 3 or email us at: