32
516514
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
25. COIN DROP
a. Single Coin Drop Removal
(1) Unlock and open service door.
NOTE: If screw type lock is used, the retainer
bracket must be removed from inside meter case.
(2) Disconnect wire harness from coin drawer
switch and disconnect coin drop at
disconnect plugs.
(3) Press in on locking tabs of service door
switch and remove switch from bracket on
meter case, as shown in Figure 13.
(4) Use a 7/16 inch socket with No. 310P4 1/4
inch Ratchet Extension Tool and remove
two locknuts holding coin drop to front of
meter case. Refer to Figure 14.
(5) Lift back end of coin drop and pull straight
back until bottom edge of drop’s front face
plate falls behind the coin drawer housing.
(6) Carefully lift complete coin drop straight
up and out of meter case.
b. Single Coin Drop Installation
Reverse removal procedures for installation.
Figure 14
Figure 13
W408SE1B
SERVICE
DOOR SWITCH
LOCKING
TAB
METER
CASE
SWITCH
BRACKET
7/1
6
"
W485SE1C
LOCKNUT
SINGLE
COIN DROP
FRONT OF
METER CASE
7/16"
SOCKET
NO. 310P4
1/4" RATCHET
EXTENSION
TOOL
1/4"
RATCHET
Summary of Contents for DAM 9
Page 1: ...DAM 9 SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 02 01 516514 ...
Page 2: ......
Page 127: ......
Page 128: ......