background image

FRONT VIEW

PARTS LIST

ITEM

PART NUMBER

DESCRIPTION

1

78-184S

Power and Motor Lighted
Rocker Switch

2

197-185S

Platen Adjustment Knob
(Pkg of 2)

3

70-012

Thermostat  Knob

4

197-232

Foot

5

197-124

Conveyor Guide

1

2

3

4

5

TROUBLE SHOOTING

PROBLEM

CAUSE

SOLUTION

Unit will not heat up.

No power to unit.

Ensure power cord is connected to

Power rocker switch

proper Receptacle and the power inlet.

light off.

Inoperable power cord.

Replace power cord.

Loose connection on power switch.

Tighten power switch connections.

Inoperable power switch.

Replace power switch.

Unit will not heat up.

Inoperable  thermostat.

Replace  thermostat.

Power rocker switch light on.

Inoperable platen.

Replace platen.

Unit heats up, but the

Loose  motor  switch  connection.

Tighten  motor  switch  connection.

conveyor does not run.

Inoperable motor.

Replace motor.

Stripped drive gear.

Replace drive gear.

Loose chain sprockets

Adjust and tighten sprockets.

Gears not meshing.

Adjust conveyor set screws (See

Conveyor Adjustments on page 3).

Inoperable motor switch.

Replace switch.

Unit under and over

Inoperable  thermostat.

Replace  thermostat.

heats (does not respond to

thermostat adjustments).

Buns under or over done.

Check platen adjustment.

Adjust  platen  for  proper  compression

(See Platen Adjustments on page 3).

Check platen temperature.

Adjust thermostat for proper temperature.

(See Thermostat Adjustment on page 

3).

13

Summary of Contents for Excalibur 197-FCE

Page 1: ...omer for parts or labor This warranty is subject to the following exceptions conditions l Service must be performed by an authorized Prince CastleServiceCenter l Any use of non genuine Prince Castle s...

Page 2: ...se sheet over the top of the platen housing making sure to have three inches of over hang See figure 3 2 Slide the release sheet holding bracket onto the top of the platen housing to securely hold the...

Page 3: ...kwise to compensate for use on thicker bread products Turn the two platen adjustment knobs counter clockwise for thinner products See figure 6 Platen Temperature The temperature of the platen can be a...

Page 4: ...MAINTENANCE MOTOR To extend the life of your replacement motor have an authorized factoryservice technician add 2 3 drops of 3 in 1 oil on a monthly basis Note See the drawing for oil wick hole locat...

Page 5: ...rable thermostat Replace thermostat Power rocker switch light on Inoperable platen Replace platen Unit heats up but the Loose motor switch connection Tighten motor switch connection conveyor does not...

Page 6: ...ight Side Shaft Carrier Adjustment Assy 4 197 457 Left Side Shaft Carrier Adjustment Assy 5 81 015 Compression Spring 6 197 467 Conveyor Slide 7 197 280 Shaft Assy 8 197 465 Driven Shaft 9 197 302 Spr...

Page 7: ...76 165 Set Screw 7 76 640 Screw 8 197 96 Left Side Bun Fence 9 73 008 Self Locking Hex Nut 73 030 Hex Nut 79 016 Flat Washer 76 033 Slotted Flat Head Screw 10 76 640 Screw 11 197 13 Lead Pan Weldemen...

Page 8: ...055 Flat Washer 7 76 040 Slotted Binder Head Screw 79 017 Split Lock Washer 73 030 Hex Nut 8 76 150 Slotted Pan Head Screw 79 094 Flat Washer 9 79 016 Flat Washer 76 095 Slotted Binder Head Screw 10...

Reviews: