Horizontal Infrared Toaster
IRT-SB-NA-1PS
IRT-SB-NA-3PS
IRT-SB-NA-1PS
2
4
IRT-SB-NA-3PS
Remove Wire Belt
Power off and Unplug the unit
1
Remove the conveyor assembly from the unit by re-
moving (2) Philips screws. Reference the
Red Arrows
.
3
Remove the Motor. Reference the motor removal on
page 17.
2
Remove all insulation from the right side of the
conveyor assembly.
4
Remove (4) nuts on the right side of the conveyor
using an 8mm nut driver. Reference the
Blue Arrows.
5
Remove (2) Philips screws to free the right side panel
of the conveyor assembly. Reference the
Green Ar-
6
Slide the conveyor belt off of the assembly. Reference
figure 1.
7
WARNING
Failure to disconnect power
from the unit before servicing
could result in severe bodily
injury or death. The ON/OFF
Switch does not disconnect
incoming power to the unit.
#
5
#
5
#
5
#
5
#
6
#
6
Figure 1
Printed in USA