background image

537-5

28rev

C-EN

 

            

Printed in USA 

2/06

 © 200

6

4

TOASTER

TX-230

E

BKCE

Power On/Off Button

Press the On/Off Button to turn the unit off.

3

Remove the lower retaining bar from the release sheet and pull
the release sheet up thru the top of the unit. Remove the upper
retaining bar from the release sheet.

WARNING

Before performing any maintenance, press the power switch to the
OFF position. If the heater is above 450°F (232°C), the display will alter-
nately show “

C

CO

OO

OL

L

” and “

O

OF

FF

F

”, and the conveyor belt will continue to

run approximately 45 minutes. When the unit has cooled sufficiently,
the display will go blank and the conveyor motor will turn off.

Unplug the power cord from the electrical receptacle.

CAUTION

This unit is not watertight. Do not clean with a water jet or jet spray. 
Do not immerse the unit in water.

1. Turn the unit off and unplug the power cord from the electrical

receptacle.

2. Wipe all stainless parts and unit with a damp cloth. DO NOT use

a green scotch bright pad cleaner, ice or water.

1

If the heater is above 450°F, the
display will alternately show

C

CO

OO

OL

L

” and “

O

OF

FF

F

”, and the convey-

or belt will continue to run approx-
imately 45 minutes. When the unit
has cooled sufficiently, the display
will go blank and the conveyor
motor will turn off.

Unplug the power cord from the
electrical outlet.

2

Remove the front cover by pulling up and off the unit. 
Set the cover aside.

Front Cover

Lower Retaining Bar

Remove release sheet

Daily Cleaning

Loosen the thumbscrews
and remove the side panel.

4

Thumbscrews

5

To release tension on the conveyor belt, 
press in and down on the roller.

Summary of Contents for TX-230EBKCE

Page 1: ...the customer for parts and labor This warranty covers on location service i e trip charges and or mileage Travel mileage is limited to 100 miles 200 Kilometers round trip one trip warranty from an au...

Page 2: ...e proper electrical receptacle All electrical connections must be in accordance with local electrical codes and any other applicable codes Important Prince Castle reserves the right to change specific...

Page 3: ...r On Off Button If the heater is above 450 F the display will alternately show C CO OO OL L and O OF FF F and the con veyor belt will continue to run approximately 45 minutes When the unit has cooled...

Page 4: ...CAUTION This unit is not watertight Do not clean with a water jet or jet spray Do not immerse the unit in water 1 Turn the unit off and unplug the power cord from the electrical receptacle 2 Wipe all...

Page 5: ...range side facing out The Teflon sheet uses both sides as the contact surface When re installing rotate the usage by turning top to bottom and or turning the sheet inside out When reassembling convey...

Page 6: ...DOWN Arrow Button and turn the unit back on When you release the Arrow Button the dis play will be in Celsius To switch from Celsius to Fahrenheit turn the unit off Press and hold the UP Arrow Button...

Page 7: ...ocated at the right hand rear of the unit Allow the unit to cool approximately 15 min utes before starting Tighten motor connection Replace motor Replace drive gear Reset limit switch Using a pencil o...

Page 8: ...537 298 Cam Bracket 17 537 379 Guide Bracket 18 537 717 LH Cam Shaft 19 537 300 LH Slide Plate 20 537 381 Conveyor Bracket 21 537 382 Conveyor Bracket 22 537 319 Ramp 23 537 336 LH Upright 24 537 335...

Page 9: ...5 537 370S Lower Bearing Package of 2 6 537 318S Lower Shaft Short 7 537 316S Lower Shaft Long 8 197 279 Pin 9 537 334 Slide Bracket 10 537 411 Upper Roller 11 537 315 Upper Shaft 12 537 317S Upper B...

Page 10: ...K BLU WHT BRN BLK WHT WHT BLK BLK BLK BLK WHT POWER CORD GRN YEL 3A FUSE BLOCK CONNECTION DETAIL USED ONLY ON TX 208 TX 240 MOTOR BLK BLK CONNECT WHITE WIRE TO PROPER MOTOR VOLTAGE TAB WHT 240V 200V J...

Reviews: