TOASTER
TX-230
E
BKCE
Troubleshooting
Unit will not heat up.
Unit heats up but conveyor
will not run.
Buns under or over done.
No power to unit.
Inoperable power cord.
Loose connection on power switch.
Inoperable power switch.
High limit switch tripped.
Loose motor connection.
Inoperable motor.
Stripped drive gear.
High limit switch tripped.
Check bun crush setting.
Verify setpoint temperature.
Dirty teflon sheet.
Make sure power cord plugged into the unit and
proper electrical receptacle.
Replace power cord.
Tighten power switch connections.
Replace power switch.
Reset limit switch. Using a pencil or pen, press
the hollow portion of the 3/8" long brown, plastic
stem located at the right-hand rear of the unit.
Allow the unit to cool (approximately 15 min-
utes) before starting.
Tighten motor connection.
Replace motor.
Replace drive gear.
Reset limit switch. Using a pencil or pen, press
the hollow portion of the 3/8" long brown, plastic
stem located at the right-hand rear of the unit.
Allow the unit to cool (approximately 15 min-
utes) before starting.
Adjust for proper compression.
Adjust setpoint for proper temperature.
Clean or replace teflon sheet.
Problem
Possible Cause
Corrective Action
L O
When the platen temperature drops 24° or
more below the setpoint temperature, the
display will switch from
R
RD
DY
Y
to
L
LO
O
. If the dis-
play remains at
L
LO
O
for 30 minutes
,,
contact an
authorized Prince Castle Service Agent.
To extend the life of the motor, add 2-3 drops
of high-temperature oil on a monthly basis.
This task can be performed by an authorized
technician.