6–21
Optional Equipment
•
NVRAM
•
INTERNAL ERROR
HAMMER DRV ERROR
Twinax Printers Only –– System Communication or Data Errors:
•
SCS Code Error
•
SCS Parameter Error
•
GRAPHIC CHECK
•
ACTIVATE LOST
•
INVALID COMMAND
•
INVALID ACTIVATE
•
INPUT QUEUE OVERRUN
PARITY ERROR
COOLING ERROR
Instruction
Indication
Yes
No
1.
Check for inoperative
hammer bank or card
cage fan, or obstructed
airflow.
COOLING ERROR
message.
Replace one at at
time until
message is gone:
inoperative fan(s),
mech driver
PCBA, CCB
PCBA.
—
GRAPHIC CHECK
Instruction
Indication
Yes
No
1.
Run a buffer print and
refer to the user’s
manual. Run the same
job that generated the
error message.
GRAPHIC CHECK
message.
Verify host data
are correct and
there are no
invalid characters.
Verify printer’s
World Trade
Language is
correct.
—
2.
Run the Translation
Table in CTPC internal
test menu and check
characters. See page
6–30.
GRAPHIC CHECK
message.
Replace one at a
time until
message is gone:
CCB, CT board,
coax or twinax
cable.
—