9
To remove the solid waste after burning, a movable grate and an ash-pan is used. The ash-pan must be emptied even before it is filled with a purpose to avoid
plugging up of the supplying feeding of the air under the grate. The ash is kept in nonburnable vessels with a cover.
When operation with the pellets is recommended at least once in every two days the customer to turn off temporarily the burner, to wait until the boiler has
cooled to safe levels of temperature, to clean the internal heat exchanging surfaces of the accumulated ash, to clean the burner, to carry out the ashes, after
which in reverse order to close the doors of the boiler and to turn the burner on.
After continuous operation ash and soot are accumulated on the walls of the boiler, especially on the heat exchanger and on the smoke pipes, whereupon the
heat transfer is decreased and the boiler loses power. As a whole the quantity of the ash and the soot depends on the quality of the used fuel and the working
conditions. If the boiler has insufficient power or it is operated at a low temperature, the amount of the soot in the process of burning increases considerably. In
the same way the shortage of the draught in the chimney influences, as well. The surface of the water heat exchanger is cleaned by means of a steel brush.
A main rule in the operation: It is better a shorter burning at full power than continuous burning at low power.
The characteristics of the operation of the pellet burner and the auger forfueling from the tank to the burner are given in its manual for installation and operation.
After termination of the heating season, the boilerand the chimney are cleaned thoroughly. The steam-boiler room shall also be cleaned and be dry.
Do dot perform any unauthori
z
ed modifications in the design
!
During repairs only original spare parts by the producers shall be used.
The guarantee is not valid for fireplaces with bulging water jackets, which are a result of the increased pressure in the system beyond the
admissible one on incorrect installation.
It is recommended that the installation be done by a skilled specialist
Last update 10.05.2012
WARRANTY CARD
The products of PRITY are made in conformity with the requirements for safe operation and effectiveness according to: Bulgarian State Standard
EN
13240:2006, BSS
EN
12815:2006, BSS
EN
13229:2006, BSS
EN
12809, BSS
EN
303-5 and correspond the approved technical documentation
The warranty period of the product is 36 (thirty six) months from the date of the sale from the trade network, provided all requirements for proper transportation,
installation and operation are observed.
For the removal of defects, the fireplace is presented to the dealer, from whom it has been purchased, as its warranty card must be obligatorily
enclosed.
All claims are satisfied, except in the following cases, when:
- it refers to formation of condensation;
- it refers to a broken glass pane or bricks;
- there is a return of flue gases (smoking);
- the requirements for installation and operation indicated in the present instructions and the installation instructions have not been observed;
- the defects have been caused during transportation;
- the fireplace has a bulging water jacket as a result of increased pressure beyond the admissible.
ATTENTION!
The warranty is valid only if this guarantee card is filled in and signed legibly in ink or a ball-point pen and stamped.
In accordance with Directive 99/44/EC of the European Parliament for sale of goods and associated guarantees, the seller shall be liable to the customer for
any
lack
of
conformity
of
goods
that
are
subject
of
the
sales
contract
.
The transportation expenses are at the expense of the customer.
Producer: "Prity 95" Ltd. Bulgaria, town of Liaskovets, M. Raycovichstr. 33
e-mail: prity95@yahoo.com, www.prity-bg.com
PACKING LIST FOR A BOILER FOR WOOD AND COAL
- body of the boiler;
- doors;
- a drawer- ash-pan;
-
cast-iron grate;
- a set of handles;
- thermostat for the primary air;
- decorative side panels;
- technical
description, instllation and operation instructions
PACKING LIST FOR A COMBINED BOILER
- body of the boiler;
- doors;
- a drawer- ash-pan;
-
cast-iron grate;
- a set of handles;
- thermostat for the primary air;
- decorative side panels;
- technical
description, instllation and operation instructions
The
fireplace
has been
delivered
in
a
good
working
condition
to
the
buyer
:
.....................................................................................................................
(Full name of the purchaser)
Adress:.........................................................................................................
Company name ...........................................................................................
City (town).....................................................................................................
Invoice No. ...................................... dated from ..........................................
PURCHASER ..................................... SELLER .........................................
(Signature and stamp)
(Signature)
(Date of the sale)