Salt room
Halogenerator
Space for
halogenerator
Long, small cross area intake
and exhaust air ducts
Installation examples
If ventilation system is perfect, and air pressure after halogenerator is 0.0 mm
H
2
O (0.0 inch H
2
O), fan can produce maximum air flow of 2.3 m
3
/min (80
CFM/min).
If air pressure inside salt room is 4.0 mm H
2
O (0.16 inch H
2
O) higher than air
pressure before halogenerator, fan can produce produce air flow of 1.0 m
3
/min
(35 CFM/min).
If air pressure inside salt room is more than 8.7 mm H
2
O (0.35 inch H
2
O) above
air pressure before halogenerator, fan will not produce air flow at all. Fan
blades will rotate, but there will be no air flow.
Installation Instructions
Salt room
Halogenerator
Space for
halogenerator
Very short, big cross area
intake and exhaust air ducts