SAFETY

General instructions

•  The products referred to in this manual 

conform to the European Community 

Directives and are therefore marked with  .

•  The unit is supplied with hazardous network 

voltage (230V~). Leave servicing to skilled 

personnel only. Never make any modifications 

on the unit not described in this instruction 

manual, otherwise you will risk an electric 

shock.

•  Connection must be made to a power supply 

system fitted with efficient earthing (Class I 

appliance according to standard EN 60598-1). 

It is, moreover, recommended to protect the 

supply lines of the units from indirect contact 

and/or shorting to earth by using residual 

current devices appropriately sized.

•  The connection to the main network of 

electric distribution must be carried out by 

a qualified electrical installer. Check that the 

main frequency and voltage correspond to 

those the unit is designed for, as given on the 

electrical data label. 

•  This unit is not for home use, only professional 

applications.

•  Never use the fixture under the following 

conditions:

 - in places subject to excessive humidity;

 - in places subject to vibrations or bumps;

 - in places with temperature above 45°C or 

below 2°C.

•  Make certain that no inflammable liquids, 

water or metal objects enter the fixture.

•  Do not dismantle or modify the fixture.

•  All work must always be carried out by 

qualified technical personnel. Contact the 

nearest sales point for inspection or contact 

the manufacturer directly.

•  If the unit has to be put out of operation 

definitively, take it to a local recycling plant 

for a environmentally safe disposal.

ATTENZIONE! 

Prima di effettuare qualsiasi 

operazione con l’unità, leggere 

con attenzione questo manuale: 

contiene informazioni importanti 

riguardo l’installazione, l’uso e la 

manutenzione dell’unità. 

SICUREZZA

Avvertenze generali

•  I prodotti a cui questo manuale si riferisce sono 

conformi alle Direttive della Comunità Europea 

e pertanto recano la sigla  .

•  Il dispositivo funziona con pericolosa tensione di 

rete (230V~). Non intervenire mai al suo interno 

al di fuori delle operazioni descritte nel presente 

manuale; esiste il pericolo di una scarica elettrica.

•  È obbligatorio effettuare il collegamento ad 

un impianto di alimentazione dotato di una 

efficiente messa a terra (apparecchio di Classe 

I secondo norma EN 60598-1). Si raccomanda, 

inoltre, di proteggere le linee di alimentazione 

dell’unità dai contatti indiretti e/o cortocircuiti 

verso massa tramite l’uso di interruttori 

differenziali opportunamente dimensionati.

•  Le operazioni di collegamento alla rete di 

distribuzione dell’energia elettrica devono 

essere effettuate da un installatore elettrico 

qualificato. Verificare che frequenza e tensione 

della rete corrispondono alla frequenza ed alla 

tensione per cui l’unità è predisposta, indicate 

sulla targhetta dei dati elettrici.

•  L’unità non per uso domestico solo per uso 

professionale.

•  Evitare di utilizzare l’unità:

 - in luoghi soggetti ad eccessiva umidità;

 - in luoghi soggetti a vibrazioni, o a possibili urti;

 - in luoghi a temperatura superiore ai 45°C o 

inferiori a 2°C.

•  Evitare che nell’unità penetrino liquidi 

infiammabili, acqua o oggetti metallici.

•  Non smontare e non apportare modifiche 

all’unità.

•  Tutti gli interventi devono essere sempre e 

solo effettuati da personale tecnico qualificato. 

Rivolgersi al più vicino centro di assistenza 

tecnica autorizzato.

•  Se si desidera eliminare il dispositivo 

definitivamente, consegnarlo per lo 

smaltimento ad un’istituzione locale per il 

riciclaggio.

WARNING!

Before carrying out any operations with 

the unit, read carefully this instruction 

manual and keep it with care for 

future reference. It contains important 

information about the installation, 

usage and maintenance of the unit.

Summary of Contents for CS500 Series

Page 1: ...Manuale Utente User Manual CS500 series Conference systems I GB ...

Page 2: ...oduzione anche parziale per propri scopi commerciali è vietata All rights reserved by Music Lights S r l No part of this instruction manual may be reproduced in any form or by any means for any commercial use Tutte le specifiche possono essere variate senza alcuna notifica Design and specifications are subject to change without notice ...

Page 3: ... 11 Uso di un auricolare Connettori Risoluzione dei problemi Specifiche tecniche 4 5 6 6 8 11 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 21 22 23 INDEX Safety General instruction Warning and precautions for fixtures 1 Description and technical specifications 1 1 Introduction 1 2 Technical specifications 1 3 Operating elements and connections 2 Installation and connections 2 1 Connecting the u...

Page 4: ...e la manutenzione dell unità SICUREZZA Avvertenze generali I prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunità Europea e pertanto recano la sigla Il dispositivo funziona con pericolosa tensione di rete 230V Non intervenire mai al suo interno al di fuori delle operazioni descritte nel presente manuale esiste il pericolo di una scarica elettrica È obbligatorio ef...

Page 5: ...g and precautions for fixtures Never try to make a direct connection between the telephone network and the CS500 conference system The maximum achievable volume gain depends on the acoustical environment and positioning of the units Beforestartinganymaintenanceworkorcleaning the unit cut off power from the main supply The information provided in this manual has been carefully checked However Music...

Page 6: ...r monitoraggio o trascrizione Output Rec stereo line telefono Input Tape in stereo line telefono Canale Insert Peso 1 65 kg Dimensioni LxAxP 364x88x144 mm 1 DESCRIPTION AND TECHNICAL SPECIFICATIONS 1 1 Introduction The CS500 Conference System represents the ide al solution for conferences congresses and meet ings It is composed by Central Unit a Chairman microphone plus a max number of 49 Delegate...

Page 7: ...requenza 45 Hz 16 000 Hz Due prese per cuffie con controllo di volume integrato Peso 0 80 kg Dimensioni LxAxP 123x62x170 mm mic esclu so CS500C Microphonic base conceived to operate as a Chairman unit characterized by a high sensitiv ity and a wide frequency response Built in 3W loudspeaker Flexible goose neck microphone length 400 mm with luminous ring Frequency Response 45Hz 16 000 Hz 2 sockets ...

Page 8: ...P PANEL Fig 1 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 4 3 2 1 3 4 1 2 CS500M 11 11 1 INTERRUTTORE ON OFF 2 INDICATORE LED DI ACCENSIONE 3 SELETTORE MODALITÀ MICROFONO MODALITÀ OPEN Permette di selezionare il numero massi mo di microfoni delegati da attivare si multaneamente 1 2 3 o 4 Il microfono deve essere acceso o spento manualmen te premendo il relativo tasto sull unità delegato 1 POWER ...

Page 9: ...fusore del presi dente delegato 13 SPINA DA PANNELLO VDE per il collegamento ad una presa di rete 100 240V 50Hz tramite il cavo di rete in dotazione OPEN MODE WITH AUTO SWITCH OFF It s permitt to select the maximum number of delegate microphones to be activated simultaneously 1 2 3 or 4 The microphone automatically switches off if the speaker does not speak for 30 sec onds The microphone can manua...

Page 10: ...N SPINA 7 POLI per il collegamento all unità precedente oppure all unità centrale Nota la lunghezza del cavo è di 2 15 m The chairman unit B has the same function as a del egate unit A with the exception of a priority button 14 MICROPHONE with red illuminated indicator ring lights when the microphone is ON 15 MICROPHONE ON OFF push button 16 LED INDICATOR lights when the microphone is on 17 VOLUME...

Page 11: ...ntral unit fig 3 Use an extension cable if it will be neces sary 2 INSTALLAZIONE E COLLEGAMENTI 2 1 Collegamento delle unità dei delegati e del presidente 2 INSTALLATION AND CONNECTIONS 2 1 Connecting the delegate and chairman units Fig 3 3 25 3 25 Gain Gain In Out Trunk in out Microphone P12 Recorder Line Telephone Insertion 100 240 V CS500M Conference System DESIGNED DISTRIBUTED BY MUSIC LIGHTS ...

Page 12: ...ig 4 si realizza attraverso l ingresso XLR 8 con l attenua tore da 50dB Questo modalità di collegamento consente l interruzione del microfono senza fili usando il tasto di priorità del presidente Put the external microphone connector in the mi crophone input 8 in the rear panel of the Central Unit Adjust the sensitivity using the GAIN con trol Note use only microphones with balanced out put Connec...

Page 13: ...trol of the recorder input of the Central Unit to adjust the sensitivity 2 4 Connecting a PA system or other audio equipment Gain In Out Recorder Line Telephone Insertion C Co DESIGNE Out In RECORD PLAY Fig 5 Gain In Out Recorder Line Telephone Insertion C Co DESIGNE In Il collegamento ad un sistema PA o ad altra ap parecchiatura audio fig 6 si effettua mediante l ingresso e l uscita RCA 10 posti ...

Page 14: ...sterio re dell unità di controllo fig 7 L accoppiatore telefonico è poi collegato alla presa telefonica a muro e ad un telefono Il collegamento ad una rete telefonica deve essere effettuato mediante un accoppiatore telefonico poiché permette un isolamento adeguato tra la rete telefonica ed il sistema CS500 Attenzione non effettuare in nessun caso un collegamento diretto tra la rete telefonica ed i...

Page 15: ... the microphone button of the delegate unit In base alla posizione del SELETTORE MODALITÀ MICROFONO 3 dell unità centrale premendo il tasto microfono 15 su un unità del delegato si attiverà il microfono fig 10 Depending on the position of the microphone mode switch 3 on the Central Unit pressing the microphone button 15 on a delegate unit will activate the delegate microphone fig 10 3 FUNZIONI E I...

Page 16: ... microphone mode Note Chairman units don t switch off automati cally fig 11 3 4 Using the priority button Pressing the priority button of the chairman unit B will be indicated by a chime tone and will de activate all active delegate units A and activates the chairman microphone fig 12 Releasing of the button will either leave the delegate units de activated or activates them again depending on pri...

Page 17: ...Note chairmen can always switch on and off his microphone and the other included in the system 3 6 Open mode with auto switch off Fig 13 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 4 3 2 1 3 4 1 2 4 3 2 1 3 4 1 2 11 11 CS500M Select the maximum number 1 2 3 or 4 of del egate microphones which can be activated by the delegates themselves at the same time If the speaker is silent for approximately...

Page 18: ... unità questo si sovrapporrà all unità del delegato in uso In modo che soltanto un microfono del delegato risulterà attivo Il microfono del presidente può sempre essere attivo 3 8 Modalità solo presidente 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 4 3 2 1 3 4 1 2 4 3 2 1 3 4 1 2 11 11 CS500M Fig 15 Only one chairman unit B can be activated Del egates A can not switch on their microphone Soltant...

Page 19: ...3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 4 3 2 1 3 4 1 2 11 11 0 1 2 3 4 5 6 7 8 9 10 11 CS500M 0 1 2 3 4 5 6 7 8 9 10 2 1 11 1 0 1 2 3 4 5 6 7 8 9 10 2 11 Fig 17 Use the built in loudspeaker 19 or a headphone to monitor the discussion Adjust the volume us ing the volume control 5 The maximum level is controlled by the setting of the volume control for delegate and chairman units Servirsi dei diffu...

Page 20: ...el depends on the setting of the volume control 4 on the Central Unit Usare il CONTROLLO VOLUME 17 per regolare il livello audio delle cuffie che possono essere collegate nelle prese posizionate a destra e a si nistra dell unità Il massimo livello dipende dalle impostazioni del controllo volume 4 dell unità centrale 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 4 3 2 1 3 4 1 2 11 11 CS500M 17 4 Fi...

Page 21: ...HTS s r l ISO 9000 2001 CERTIFIED COMPANY MANUFACTURED IN PRC 2 3 2 1 Headphone Jack plug 1 Tip 2 Ring 3 Sleeve ground RCA signal connector 1 Signal 2 Screen 1 2 Connector 7 pin 1 Audio contribution line 2 Ground 3 Audio distribution line 4 Control line 1 5 Control line 2 6 V supply 7 V supply 1 3 XLR signal connector 1 Ground 2 Signal 3 Signal 1 4 2 5 3 6 7 1 6 4 2 5 3 7 3 1 6 5 2 4 7 Yellow Drai...

Page 22: ...me relativo ai diffusori delle unità dei delegati e del presidente sull unità centrale sia in posizione corretta Microfono attivo o cuffie collegate Le unità con microfoni attivi o cuffie collegate hanno le casse spente PROBLEM POSSIBLE CAUSE SOLUTION Temporary no microphone reaction and no sound or distorted sound from unit loudspeakers Overload line Reduce load on the line reducing the number of...

Page 23: ...and R channel Output level 20 dBV 5 dBV nominal maximum Output impedance 500 Ω EXTERNAL MICROPHONE INPUT BALANCED Input sensitivity 56 dBV 6 dBV via included adapter Input sensitivity adjustment 6 dB 6 dB Phantom supply 12V 1V 2 x 680 Ω 2 MONITOR LOUDSPEAKER Output level at 0 5 m 72 dB SPL 82 dB SPL nominal maximum Frequency response 320 Hz 10 kHz 10 dB ref 1kHz Impedance 25 Ω Volume control 50 dB...

Page 24: ...Maximum per trunk output 25 Mounting free standing on a table top or mounted in a 19 rack requires 3U Height Units Dimensions WxHxD 88x144x364 mm Weight 1 65 kg COMBINED UNITS Delegate microphones with transmission links to delegate headphones and auxiliary outputs GENERAL Frequency response 125 Hz 12 5 kHz tolerances acc to IEC 914 standard Total harmonic distortion at overload at nominal input l...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ... 2009 Music Lights S r l PROAUDIO è un brand di proprietà della Music Lights S r l PROAUDIO is a brand of Music Lights S r l company MUSIC LIGHTS S r l Phone 39 0771 72190 www musiclights it ...

Reviews: