V6402, V6404, V6406,V6408
and V6418 HD converters
60
Issue 6
5.5
Configuration – CONFIG
Main
Menu
Sub
Menu
Value
Comment
V6402
V6404
V6406
V6408
V6418
CONFIG
GPI
GPI OFF
n
GPI has no function
ü
ü
ü
ü
ü
GPI SDI1
Activate to select I/P 1
GPI SDI2
Activate to select I/P 2
GPI BARS
Activate to O/P Bars
(SY)
Banner
On
n
This enables the Warning
Msg.
Banner.
ü
ü
ü
ü
ü
Off
Op Mode
Normal
n
Manual output std
selection
ü
Up/Down
Up/Down conversion only
Def Std
720p59
n
ü
720p60
720p29
720p30
720p50
720p25
720p23
720p24
1080i59
1080i60
1080p29
1080p30
1080i50
1080p25
1080p23
1080p24
1080sf23
1080sf24
1035i59
1035i60
525i59
625i50
Default Standard
This is the default O/P
standard that will be
selected when no valid
Video Input signal is
present.
This is useful when the
unit is used as a ‘stand-
alone’ test pattern
generator. It allows the
operator to step through
all supported modes (see
list on the left), resulting
in an instant change of
the Output standard.
DefIpStd
729p59
n
Default Standard
ü
ü
ü
720p60
720p29
This is the default I/P
standard
720p30
that will be selected when
no
720p50
valid Video Input signal
is
720p25
present.
720p23