referenCe
EmpyrE ElItE Xt InstallatIOn and OpEratIOn manual
23
Red
White
Probe-
2 wire
black
cable
Probe
Power
7 8
10 11
Com NO
White
Red
1
2
3
4
3
5
1
4
7
8
6
2
10
9
Red
Wiring Diagram
818492 - R0
Limit Switch - 815822
1.
Blower Switch - 800836
2.
Indicater Light - 806481
3.
Timer Unit - 817482
4.
Temp Controller A - 810268
5.
Probe Well - 806455
6.
Snap Disc - 816271
7.
Blower - 814185
8.
Furnace Power Cord
9.
Probe - 812424
10.
Black
Orange
1
White
Orange
Yellow
Blue
Blue
Blue
Yellow
Purple
White
Red
Orange
Ground
}
110 volts
AC 60Hz
Black power line
White neutral line
NO NC
2
CAUTION
DO NOT CONNECT THE ELECTRICAL COMPONENTS OF THIS UNIT TO ANY OTHER
ELECTRICAL APPLIANCE.
DO NOT MODIFY THE ELECTRICAL COMPONENTS OR ANY OTHER PART OF
THIS FURNACE. MODIFICATION TO ANY PART OF THIS FURNACE WILL VOID THE
WARRANTY.
Wiring diagram
818492R00
1. Limit Switch - 815822
2. Blower Switch - 800836
3. Indicator Light - 806481
4. Timer Unit - 817482
5. Temp Controller A - 810268
6. Probe Well - 806455
7. Snap disc - 816271
8. Blower - 814185
9. Furnace Power Cord
10. Probe - 812424
Summary of Contents for Empyre Elite XT
Page 1: ...Installation and Operation Instructions Empyre Elite XT Model 100 and 200...
Page 2: ......
Page 31: ......