FP2600-T41 User Manual
3-9
Installation and Wiring
SW1-6
This controls is used as the touch screen Click sound's ON/OFF switch.
When this is set to ON, a click will sound every time the touch panel is touched.
SW1-5
This switch controls the Automatic Backlight OFF mode.
When this switch is ON, and if there is no SIO transmission or touch operation
performed for 5 minutes, the backlight turns off automatically. It will remain OFF until
another SIO transmission or touch operation takes place, at which time the backlight
automatically turns back on.
If the FP unit is frequently not used, please set this switch ON to extend the life of the
backlight. Also, if a display related command is transmitted by the SIO, this Automatic
Backlight OFF mode will be automatically disabled.
FP does not have Power Save Mode.
SW1-7
This is a switch to shift as adjustment mode at factory.
Please set this switch OFF when the FP unit is used.
SW1-8
This is a switch to change the data input (command control) of the touch panel.
Data output and command input/output will be performed from the USB connector
when this is ON and from the RS232C connector when it is OFF.
3-3-2 Front LED Operation Mode Display
L ED L ig h t
O F F
G re e n
O ra n g e
G re e n /Re d
O ra n g e
Co n d itio n
lig h tin g
b lin kin g
b lin kin g
P a n e l
Power O F F
Power O N
Power O N
Power O N
Power O N
Ba cklig h t
Norm al
Norm al
Bulb burned out
Bulb burned out
Im a g e in p u t
Yes
No
Yes